Comparaison des mesures des températures cryogéniques à l'intérieur ainsi qu'à l'extérieur de la tuyauterie.

Comparison of cryogenic temperature measurements inside and outside the piping.

Auteurs : SÜSSER M., WÜCHNER F.

Résumé

The design of cryogenic facilities needs careful investigations of all components with regard to reliability and economy of the operation. Leak tightness is a fundamental necessity in cryogenics, because leaks may impair or even prevent the operation of the complete cryogenic facility. Allergic components in cryogenic systems can be temperature sensors which, depending on certain restrictions, can be installed in different ways. The in-tube installation represents a more accurate temperature measurement of the fluid compared with the on-tube installation. However, the in-tube installation is more crucial and risky due to the fact that the sensor feedthrough can leak.

Détails

  • Titre original : Comparison of cryogenic temperature measurements inside and outside the piping.
  • Identifiant de la fiche : 2006-0043
  • Langues : Anglais
  • Source : Proceedings of the nineteenth International Cryogenic Engineering Conference. ICEC 19.
  • Date d'édition : 22/07/2002

Liens


Voir d'autres communications du même compte rendu (71)
Voir le compte rendu de la conférence