Document IIF

Comparaison systématique de la performance de deux frigorigènes : R134a et R410A.

Systematic comparison of performance of two refrigerants R134a and R410A.

Numéro : pap. n. 4.6

Auteurs : AMMARI H., HAMMAD M., HADDADEEN D., et al.

Résumé

A systematic study of performance of a refrigerator using two refrigerants R134a and R410A has been conducted. The R134a was the original design refrigerant, while the R410A was the drop-in refrigerant. The study was performed on a small refrigerator charged with each refrigerant alone at nearly same ambient conditions. Temperatures at various locations in the refrigeration system were measured using thermocouples during the running of the experiments, and the data collected were processed into performance refrigeration parameters. The results have indicated that both of the refrigeration capacity and coefficient of performance were higher for the refrigerant R410a by about 3 and 7%, respectively.

Documents disponibles

Format PDF

Pages : 11 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Systematic comparison of performance of two refrigerants R134a and R410A.
  • Identifiant de la fiche : 30006071
  • Langues : Anglais
  • Source : 4th Jordanian IIR International Conference on Refrigeration and Air Conditioning. Proceedings: Amman, Jordan, September 10-12, 2012.
  • Date d'édition : 10/09/2012

Liens


Voir d'autres communications du même compte rendu (28)
Voir le compte rendu de la conférence