Résumé
Refrigeration equipment manufacturers are now developing their next generation refrigeration units with low GWP refrigerants to reduce the total carbon footprint and energy consumption. Alternatives which balance GWP, flammability and efficiency are being extensively evaluated for different applications. In this paper, the performance of dropping-in R1234yf in a reefer refrigeration unit designed for R134a is numerically assessed. Even though the R1234yf is already widely used in many other applications, its utilization in marine applications is challenging due to the wide operating range of operating conditions (set point from -30°C up to 30°C). The paper presents the analysis of the simulations for different scenarios: operation in extreme conditions, performance sensitivity to evaporator superheat and to the total subcooling. Total subcooling is very high in reefers compared to other applications, leading the unit with R1234yf to deliver even higher capacity, up to 10%, compared to R134a.
Documents disponibles
Format PDF
Pages : 12
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Numerical performance assessment of a reefer unit equipped with R1234yf as drop-in replacement for R134a.
- Identifiant de la fiche : 30031771
- Langues : Anglais
- Sujet : Technologie, Alternatives aux HFC
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Date d'édition : 21/08/2023
- DOI : http://dx.doi.org/10.18462/iir.icr.2023.0097
Liens
Voir d'autres communications du même compte rendu (491)
Voir le compte rendu de la conférence
Indexation
-
Very low GWP refrigerant R-516a for R-134a repl...
- Auteurs : KIM S., CROSBY K., RODOWSKI D.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Evaluation of compressor reliability for HFO re...
- Auteurs : KAWAE A., MATSUURA H., TANAKA M.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 25th International Compressor Engineering Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Low GWP fluids for replacing R134a in an air-co...
- Auteurs : LI H., PENG J.
- Date : 01/09/2021
- Langues : Anglais
- Source : 6th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Comparison of transient response of an evaporat...
- Auteurs : GARCÍA J., ALI T., MOREIRA DUARTE W., et al.
- Date : 07/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 91
- Formats : PDF
Voir la fiche
-
New thermodynamic mixture models for HFO-contai...
- Auteurs : BELL I. H.
- Date : 10/07/2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche