Document IIF
Détermination en laboratoire de la concentration dangereuse en R40 dans des systèmes au HFC-134a, application au refroidissement de conteneurs intermodaux et technique de pacification.
Laboratory determination of hazardous R40 concentration in HFC-134a systems, application to intermodal container refrigeration and pacification technique.
Numéro : pap. n. 805
Auteurs : LAWTON A. R., CLARKE P.
Résumé
Results of extensive testing of HFC-134a and R40 (chloromethane) mixtures and their reaction with aluminium are presented. The interaction of R40 with aluminium is of particular interest as it can cause the formation of trimethyl aluminium, a pyrophoric chemical which can place service technicians at risk. Investigation of the chemical processes is provided along with a pacification process of a system that has reacted after being contaminated with R40. The reaction mechanism in in-service refrigeration systems is explored and the application of laboratory observations is provided. Results have shown that the reaction is difficult to trigger and it is likely that likely that 35% of a standard charge size substituted by chloromethane is needed to consume all of the oil and, in the absence of moisture, allow a pyrophoric reaction to take place. Pacification is achieved using isopropyl alcohol which allows the system to be safely decommissioned by technicians.
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Laboratory determination of hazardous R40 concentration in HFC-134a systems, application to intermodal container refrigeration and pacification technique.
- Identifiant de la fiche : 30026213
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Date d'édition : 24/08/2019
- DOI : http://dx.doi.org/10.18462/iir.icr.2019.0805
Liens
Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFC;
Conteneurs et emballages - Mots-clés : R134a; Sécurité; Contamination; Réaction chimique; Aluminium; R40; Essai; Conteneur frigorifique
-
Riesgo debido a la utilización de refrigerantes...
- Auteurs : CAVALIER G., LAWTON R.
- Date : 02/2013
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 41 - n. 455
- Formats : PDF
Voir la fiche
-
Risques liés à l'utilisation de frigorigènes co...
- Auteurs : IIF-IIR, CAVALIER G., LAWTON R.
- Date : 11/2012
- Langues : Anglais, Français
- Source : IIF, Note Inf. Technol. Froid / IIR, Inf. Note Refrig. Technol. / www.iifiir.org - n. 23
- Formats : PDF
Voir la fiche
-
Counterfeit refrigerant in food transportation ...
- Auteurs : LAWTON A. R., MARSHALL N., CLARKE P.
- Date : 02/04/2013
- Langues : Anglais
- Source : 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
Voir la fiche
-
Alternative lower GWP refrigerants for HFC-134a...
- Auteurs : LAWTON A. R., RHODES C.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
AHRI white paper: reports of R134a contaminated...
- Auteurs : AHRI
- Date : 2013
- Langues : Anglais
- Source : AHRI
Voir la fiche