Document IIF

Développement d'un congélateur au CO2 à usage commercial.

Development of a CO2 freezer for commercial use.

Auteurs : IMAI S., TSUIHIJI R., ISHII T., et al.

Résumé

Some cycle enhancements are necessary for CO2 refrigeration cycle to utilize it for low-temperature applications because basic CO2 refrigeration cycle is not efficient as conventional cycle. The authors have developed an efficient CO2 refrigeration unit with injection cycle, hermetic two-stage rotary compressor and expansion value control algorism for this cycle. System performance was evaluated for the prototype freezer with CO2 refrigeration unit. As a result, the average power consumption of the prototype freezer was reduced by about 18% compared with conventional Sanyo freezer model (SRF-G1283S) using R404A refrigerant under ambient temperature condition of 30°C.

Documents disponibles

Format PDF

Pages : 2010-2

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Development of a CO2 freezer for commercial use.
  • Identifiant de la fiche : 2010-1498
  • Langues : Anglais
  • Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
  • Date d'édition : 12/04/2010

Liens


Voir d'autres communications du même compte rendu (84)
Voir le compte rendu de la conférence