Recommandé par l'IIF / Document IIF

Développement de congélateurs commerciaux efficaces sur le plan énergétique en utilisant des compresseurs de pointe, des frigorigènes naturels et des couvercles vitrés à faible émissivité.

Development of energy efficient sales freezers by using state-of-the-art compressors, natural refrigerants and low emissivity glass cover.

Résumé

The introduction of Ecodesign criteria and energy labeling schemes in the EU has started a race for increasing the energy efficiency of commercial sales cabinets.
DTI has investigated the role of the refrigeration system and the cover glass for plug-in sales cabinets. Tests were conducted for cabinets with curved glass lids and for cabinets with horizontal flat glass lids.
By optimizing the refrigeration system and using a new compressor for R600a, the energy consumption was reduced by 24.5 %.
By installing a new glass cover with super low emissivity at the lower surface, the energy consumption was reduced by an additional 15,8 % compared to the prototype with new compressor. For horizontal glass, this creates a still layer of air under the glass which helps to reduce the heat transfer through the lids even more.
Static air freezers with horizontal lids with one layer of glass with super low emissivity coating insulate the cabinet like a solid lid or a night cover.

Documents disponibles

Format PDF

Pages : 8 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Development of energy efficient sales freezers by using state-of-the-art compressors, natural refrigerants and low emissivity glass cover.
  • Identifiant de la fiche : 30029702
  • Langues : Anglais
  • Sujet : Technologie
  • Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
  • Date d'édition : 13/06/2022
  • DOI : http://dx.doi.org/10.18462/iir.gl2022.0095
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (169)
Voir le compte rendu de la conférence