Document IIF
Étude comparative expérimentale de frigorigène à faible GWP alternatif au R134a dans une chambre froide.
Comparative experimental study of low GWP alternative for R134a in a walk-in cold room.
Auteurs : KABEEL A. E., KHALIL A., BASSUONI M. M., et al.
Type d'article : Article, Article de la RIF
Résumé
The environmental problems induced by the ongoing increase in the global worming potential (GWP) pose a significant interest among researchers. It was found that, the currently used refrigerants are with high GWP (National Refrigerants Inc., 2004), so that it becomes necessary to search for alternatives to these refrigerants that can properly operate on the same systems but with low GWP. Therefore a walk-in cold room working with vapor compression cycle is constructed and tested in this paper. The performance of R134a refrigerant with high GWP is compared to another low GWP refrigerant R1234ze in a trail to provide a solution of the problem of high GWP of refrigerants currently used in cold rooms. The results obtained in this study have shown that, the cooling capacity of R1234ze was lower than that of R134a by 2% to 13%. The lowest evaporating temperature that could be reached for R1234ze is -13 °C while the lowest temperature of R134a is -30 °C. Regarding the power consumption, R1234ze has lower power consumption than R134a by about 9% to 15% therefore it can be concluded that R 1234ze can be recommended to be used at high and medium evaporating temperature after carrying out the suitable modifications on the refrigeration cycle.
Documents disponibles
Format PDF
Pages : 303-312
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Comparative experimental study of low GWP alternative for R134a in a walk-in cold room.
- Identifiant de la fiche : 30018590
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 69
- Date d'édition : 09/2016
Liens
Voir d'autres articles du même numéro (37)
Voir la source
Indexation
-
ABAISSER LES DEPENSES D'ENERGIE POUR LES CHAMBR...
- Date : 02/1988
- Langues : Allemand
- Source : Temp. Tech. - vol. 26 - n. 1-2
Voir la fiche
-
Isolation thermique des chambres froides : étud...
- Auteurs : MIRONTCHUK Û. A.
- Date : 2004
- Langues : Russe
- Source : Holodil'na Tehnika i Tehnologiâ - n. 3
Voir la fiche
-
The reduction of energy consumption due to fans...
- Auteurs : EDWARDS B. J., FLEMING A. K.
- Date : 01/1979
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 2 - n.1
- Formats : PDF
Voir la fiche
-
An experimental study of R-454C pull-down perfo...
- Auteurs : MOSTAFA A., HASSANAIN M., ELGENDY E.
- Date : 10/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 130
- Formats : PDF
Voir la fiche
-
NON-ETANCHEITE A L'AIR DES PAROIS D'ENTREPOTS F...
- Date : 05/1983
- Langues : Néerlandais
- Source : Koeltech. Klim. - vol. 76 - n. 5
Voir la fiche