IIR document

Comparative experimental study of low GWP alternative for R134a in a walk-in cold room.

Author(s) : KABEEL A. E., KHALIL A., BASSUONI M. M., et al.

Type of article: Article, IJR article

Summary

The environmental problems induced by the ongoing increase in the global worming potential (GWP) pose a significant interest among researchers. It was found that, the currently used refrigerants are with high GWP (National Refrigerants Inc., 2004), so that it becomes necessary to search for alternatives to these refrigerants that can properly operate on the same systems but with low GWP. Therefore a walk-in cold room working with vapor compression cycle is constructed and tested in this paper. The performance of R134a refrigerant with high GWP is compared to another low GWP refrigerant R1234ze in a trail to provide a solution of the problem of high GWP of refrigerants currently used in cold rooms. The results obtained in this study have shown that, the cooling capacity of R1234ze was lower than that of R134a by 2% to 13%. The lowest evaporating temperature that could be reached for R1234ze is -13 °C while the lowest temperature of R134a is -30 °C. Regarding the power consumption, R1234ze has lower power consumption than R134a by about 9% to 15% therefore it can be concluded that R 1234ze can be recommended to be used at high and medium evaporating temperature after carrying out the suitable modifications on the refrigeration cycle.

Available documents

Format PDF

Pages: 303-312

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Comparative experimental study of low GWP alternative for R134a in a walk-in cold room.
  • Record ID : 30018590
  • Languages: English
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 69
  • Publication date: 2016/09

Links


See other articles in this issue (37)
See the source