ETUDE DU GEL BIDIMENSIONNEL A L'EXTERIEUR D'UN TUBE TRANSPORTANT UN REFRIGERANT.

ANALYSIS OF TWO-DIMENSIONAL FREEZING ON THE OUTSIDE OF A COOLANT-CARRYING TUBE.

Auteurs : SPARROW E. M., HSU C. F.

Type d'article : Article

Résumé

L'ACCROISSEMENT DE LA TEMPERATURE AXIALE DU REFRIGERANT A POUR CONSEQUENCE UN PROBLEME BIDIMENSIONNEL DU GEL AUTOUR DU TUBE. DANS LA PREMIERE PARTIE DU TEXTE, ON DECRIT LES PROCEDURES POUR INCORPORER L'EQUATION D'ENERGIE DU REFRIGERANT ET LES DIVERSES CONDITIONS LIMITES. UNE SOLUTION ANALYTIQUE EST OBTENUE POUR DEMARRER LES SOLUTIONS NUMERIQUES. L'ETUDE NUMERIQUE EST FOCALISEE SUR DES REFRIGERANTS GAZEUX. LES RESULTATS OBTENUS CONCERNENT L'EPAISSEUR DE LA COUCHE GELEE, LA TEMPERATURE MOYENNE DU REFRIGERANT, LA TEMPERATURE DE LA PAROI DU TUBE, L'ENERGIE EXTRAITE LORS DU CHANGEMENT DE PHASE, LE NOMBRE DE STANTON DU REFRIGERANT, LE NOMBRE DE BIOT ET LES NOMBRES DE STEFAN DE LA PHASE SOLIDE ETANT LES PARAMETRES. LES RESULTATS NE SONT PAS TRES SENSIBLES AUX NOMBRES DE STANTON ET DE STEFAN MAIS SONT INFLUENCES PAR LE NOMBRE DE BIOT.

Détails

  • Titre original : ANALYSIS OF TWO-DIMENSIONAL FREEZING ON THE OUTSIDE OF A COOLANT-CARRYING TUBE.
  • Identifiant de la fiche : 1982-0082
  • Langues : Anglais
  • Source : International Journal of Heat and Mass Transfer - vol. 24 - n. 8
  • Date d'édition : 08/1981