Experimental study on parallel-flow condensers applied on food refrigerated display cabinet.

[In Chinese. / En chinois.]

Author(s) : LIU J., ZOU Y., QI Y.

Type of article: Article

Summary

Single and double row parallel-flow condensers had been used in the refrigerated display cabinet. This system was compared to the refrigerator system which used fin-and-tube condenser. This study show that the compressor average power consumption in a cycle was minimum when refrigerant was charged 550g, 650g and 800g respectively in the refrigerator systems which used single, double row parallel-flow and fin-and-tube condensers. The system with double row parallel-flow condenser consumed the least power among the three systems, and the system with single row parallel-flow condenser was almost the same with the system with fin-and-tube condenser. In the air side, parallel-flow condensers’ performance was better than the fin-and-tube condenser. The single and double row parallel-flow condensers only have a quarter and a half volume of the fin-and-tube condenser in the experiment, which indicates that parallel-flow condenser will be a good solution for the insufficient heat exchange capacity in the harsh environment and reduction of the cost when applied in refrigerator.

Available documents

Format PDF

Pages: 83-90

Available

  • Public price

    20 €

  • Member price*

    15 €

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details


Links


See other articles in this issue (9)