Document IIF

Etude expérimentale de la performance des congélateurs commerciaux utilisant le frigorigène HC-600a.

Experimental investigation on the performance of commercial freezers using refrigerant HC-600a.

Résumé

The paper presents a comparative experimental study on the performance of HC-600a and HFC-134a in commercial freezers. One chest freezer, a 170 liters bottle cooler/ice cream cabinet, was tested and evaluated. Pull down and energy consumption tests were performed for the original HFC-134a unit, and for a HC-600a prototype. Results of the tests show that the HC-600a prototype achieved a lower internal temperature and had a lower energy consumption.

Documents disponibles

Format PDF

Pages : 2000-1

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental investigation on the performance of commercial freezers using refrigerant HC-600a.
  • Identifiant de la fiche : 2002-0050
  • Langues : Anglais
  • Source : Final proceedings of the 4th IIR-Gustav Lorentzen Conference on Natural Working Fluids at Purdue.
  • Date d'édition : 25/07/2000

Liens


Voir d'autres communications du même compte rendu (65)
Voir le compte rendu de la conférence