Document IIF
Étude numérique du refroidissement par aspersion d’un refroidisseur d’air CNG monté sur patins sous l’influence d’un vent latéral.
Numerical investigation on spray cooling of skid-mounted CNG air cooler under the influence of crosswind.
Résumé
Air cooler is a critical heat dissipation equipment applied in the field of oil and gas storage, which is mainly used to control the temperature during oil and gas storage and ensure the safety of oil and gas storage. After the installation of the spray cooling system on the skid-mounted compressed natural gas (CNG) air cooler Suqiao gas storage, the inlet air temperature of the air cooler decreases, resulting in reduced compressor power consumption. This effectively addresses the issue of unit shutdown due to high temperatures during the summer. However, the actual spray effect on-site reveals the impact of crosswinds, which poses a challenge. In this study, the flow field and causes of the skid-mounted CNG air cooler equipped with a spray cooling system under the influence of crosswinds are analyzed. Additionally, a solution involving the installation of a baffle is proposed. The results highlight that crosswinds have an adverse effect on outdoor spray cooling. With the installation of the baffle, the low-temperature area expands, resulting in lower temperatures. The cooling range is approximately 2 K, effectively counteracting the negative effects of crosswinds.
Documents disponibles
Format PDF
Pages : 59-69
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Numerical investigation on spray cooling of skid-mounted CNG air cooler under the influence of crosswind.
- Identifiant de la fiche : 30032791
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 167
- Date d'édition : 11/2024
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2024.07.025
Liens
Voir d'autres articles du même numéro (22)
Voir la source
Indexation
-
Ice plug employed on subsea pipeline bend durin...
- Date : 22/12/1997
- Langues : Anglais
- Source : Oil Gas J. - vol. 95 - n. 51
Voir la fiche
-
Venezuelan refinery outsources new hydrogen plant.
- Auteurs : BAILEY T. C., HEMMINGS J. W.
- Date : 16/03/1998
- Langues : Anglais
- Source : Oil Gas J. - vol. 96 - n. 11
Voir la fiche
-
Salted drilling mud helps prevent casing collap...
- Auteurs : KUTASOV I. M.
- Date : 31/07/1995
- Langues : Anglais
- Source : Oil Gas J. - vol. 93 - n. 31
Voir la fiche
-
Retrofit your ethylene unit: the Chevron experi...
- Auteurs : PRICKETT R. D., BUSH K. E., CRUEY G.
- Date : 03/1998
- Langues : Anglais
- Source : Hydrocarbon Processing - vol. 77 - n. 3
Voir la fiche
-
LA COMPRESSION MECANIQUE DE VAPEUR DANS LES IND...
- Date : 06/1990
- Langues : Français
- Source : Ind. électr. Inf., Cah. Ind. aliment. - n. 21
Voir la fiche