Document IIF

Évaluation comparative du risque d'un conditionneur d'air [split] et d'un réfrigérateur fonctionnant aux frigorigènes hydrocarbures.

Comparative evaluation of risk of a split air conditioner and refrigerator using hydrocarbon refrigerants.

Auteurs : COLBOURNE D., SUEN K. O.

Type d'article : Article, Article de la RIF

Résumé

The use of flammable refrigerants, such as R290 (propane), as an alternative to HCFC R22 in room split air conditioners (SACs) is being pursued. Concerns exist that current experience for safe application of R290 SACs is minimal. Conversely, there is extensive application of domestic and small commercial hydrocarbon refrigeration systems; this experience can help determine safety implications to wider use of R290 SACs. This study uses established quantitative risk assessment methods to estimate frequency and severity of ignition of R600a domestic refrigerators, which corresponds to current experience. The methodologies are also applied to R290 SACs based on their particular characteristics to estimate the associated risk. Results show the frequency and severity of ignition of SACs are significantly lower than domestic refrigerators due to the SAC installation characteristics being more conducive for dispersion of leaked refrigerant and less potential for confinement of a flammable mixture in the event of ignition.

Documents disponibles

Format PDF

Pages : 295-303

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Comparative evaluation of risk of a split air conditioner and refrigerator using hydrocarbon refrigerants.
  • Identifiant de la fiche : 30016313
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 59
  • Date d'édition : 11/2015

Liens


Voir d'autres articles du même numéro (27)
Voir la source