Évaluation énergétique du CO2 comparé aux frigorigènes fluorés dans un meuble MT avec un système à détente directe.

CO2 vs. fluorinated refrigerants energy evaluation in a MT cabinet with DX-system.

Numéro : pap. 1119

Auteurs : SÁNCHEZ D., CATALÁN-GIL J., LLOPIS R., et al.

Résumé

Due to its low GWP100, CO2 is being implanted as a long-term solution in commercial refrigeration. However, the reduced direct effect of CO2 is contradicted by its high indirect effect - caused by the energy consumption of the refrigerating plants, especially in warm climates such as Spain -. The need for experimental data that compares the energy consumption of a DX-system using CO2 as a refrigerant with the current fluorinated refrigerants is the aim of this work, where two experimental facilities designed and
optimized for CO2 and R134a have been experimentally tested at three heat rejection temperatures using a cabinet for fresh product as cooling load. Results from experimental tests confirm that the performance of simplified CO2-systems is far away from HFC-systems and, therefore, it justifies the need to adopt new configurations to improve its energy consumption. In this sense, an alternative CO2 configuration based on double IHX has been presented and experimentally tested.

Documents disponibles

Format PDF

Pages : 8

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : CO2 vs. fluorinated refrigerants energy evaluation in a MT cabinet with DX-system.
  • Identifiant de la fiche : 30023487
  • Langues : Anglais
  • Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
  • Date d'édition : 18/06/2018
  • DOI : http://dx.doi.org/10.18462/iir.gl.2018.1119

Liens


Voir d'autres communications du même compte rendu (177)
Voir le compte rendu de la conférence