Document IIF
Evaluation du CO2 comme fluide secondaire comme option alternative aux systèmes à détente directe dans un meuble MT.
CO2 as secondary fluid as alternative to DX-systems energy evaluation in a MT cabinet.
Numéro : pap. 1118
Auteurs : SÁNCHEZ D., CABELLO R., LLOPIS R., et al.
Résumé
The current F-Gas Regulation restricts the use of fluorinated refrigerants with high GWP100 in commercial refrigeration where centralized refrigeration is commonly use. Alternatives to make these systems more ecofriendly are mainly focused in the use of low-GWP refrigerants as natural refrigerants or flammable fluorinated substances. Since flammability makes centralized DX-systems not suitable for commercial refrigeration, the use of secondary fluids based on brines (water base) or volatile fluids (CO2 mainly) is presented as a long-term solution or transitioning towards more sustainable refrigeration systems. Accordingly, the aim of this work is to compare the energy consumption of three commercial refrigeration systems. The first one is a classic R134a DX-system, the second one is a basic R744 DX-system with an IHX, and finally, the last one, is a HFC indirect expansion system using CO2 as secondary fluid. This comparison has been experimentally assessed in a medium temperature cabinet at three heat rejection temperatures.
Documents disponibles
Format PDF
Pages : 9
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : CO2 as secondary fluid as alternative to DX-systems energy evaluation in a MT cabinet.
- Identifiant de la fiche : 30023486
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Date d'édition : 18/06/2018
- DOI : http://dx.doi.org/10.18462/iir.gl.2018.1118
Liens
Voir d'autres communications du même compte rendu (177)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
CO2;
Supermarchés, meubles de vente - Mots-clés : Durabilité; R134a; Consommation d'énergie; Comparaison; Meuble de vente; R744; Experimentation; CO2
-
CO2 vs. fluorinated refrigerants energy evaluat...
- Auteurs : SÁNCHEZ D., CATALÁN-GIL J., LLOPIS R., et al.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche
-
CO2 as secondary fluid as alternative to DX-sys...
- Auteurs : SÁNCHEZ D., CABELLO R., LLOPIS R., et al.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche
-
Sustainable low carbon heating and cooling for ...
- Auteurs : COLOMBO I., MAIDMENT G. G., CHAER I., et al.
- Date : 07/2011
- Langues : Anglais
- Formats : PDF
Voir la fiche
-
Energy evaluation of the mechanical subcooling ...
- Auteurs : NEBOT-ANDRÉS L., LLOPIS R., CATALÁN-GIL J., et al.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche
-
Development of a transcritical R-744 bottle coo...
- Auteurs : CECCHINATO L., CORRADI M., FORNASIERI E., et al.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche