Évaluation expérimentale du HC-290 comme frigorigène de remplacement immédiat du HCFC-22 dans les conditionneurs d'air de type split.
Experimental assessment of HC-290 as a drop-in substitute to HCFC-22 in a split air conditioner.
Numéro : pap. n. 11
Auteurs : SARAVANAN A. L., LAL D. M.
Résumé
A widely used refrigerant in split air conditioning units, the HCFC-22 has to be phased out by 2030 in all Article 5 countries under the Montreal Protocol. Propane (HC-290) is an alternative for HCFC-22. A 5.25 kW Split air conditioner without liquid receiver designed for HCFC-22 was retrofitted with HC-290 and tested under DT, ETA, ETB condition. Under drop-in tests, 4 suction line lengths viz: 12.37m, 19.1m, 23.75m, 30.1m were considered. Considering safety norms & density of HC-290 the charge quantity for HC-290 was taken to be 50% of the original HCFC-22 charge. The results show that as the suction line length increases ,the refrigeration capacity of propane reduces by 18.6% for lower operating conditions and 10.0% for the higher operating condition. The power consumption with HC-290 was lower by 4.28%. The COP with HC-290 was 17.8% higher for the lower operating conditions and 10.96% higher for the higher operating condition.
Documents disponibles
Format PDF
Pages : 7 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental assessment of HC-290 as a drop-in substitute to HCFC-22 in a split air conditioner.
- Identifiant de la fiche : 30006404
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.
- Date d'édition : 25/10/2012
Liens
Voir d'autres communications du même compte rendu (21)
Voir le compte rendu de la conférence
-
Flammable refrigerant leakage hazards control f...
- Auteurs : NING Q., HE G., FAN M., XIONG J., LI X.
- Date : 12/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 144
- Formats : PDF
Voir la fiche
-
Serviceability issues asociated with R407C refr...
- Auteurs : STANBOULY S., WESOLOWSKI A.
- Date : 23/07/1996
- Langues : Anglais
- Source : Proceedings of the 1996 Purdue International Refrigeration Conference.
Voir la fiche
-
Experimental assessment of HC-290 as a drop-in ...
- Auteurs : DEVOTTA S., PADALKAR A. S., SANE N. K.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche
-
Use of peripheral fins for R-290 charge reducti...
- Auteurs : RIBEIRO G. B., BARBOSA J. Jr
- Date : 10/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 106
- Formats : PDF
Voir la fiche
-
R290 leakage hazards assessment of a 1 HP split...
- Auteurs : NING Q., HE G., SUN W., FAN M., LI X., HONG Z.
- Date : 07/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 139
- Formats : PDF
Voir la fiche