Résumé
F-Gas Regulation has fixed a GWP limit of 150 for centralized refrigeration systems with capacity over 40 kW in Europe from 2022 on, meaning the end of R-134a as primary refrigerant in direct R-134a/CO2 cascade systems. They can be reconverted into indirect cascades using a secondary loop, bringing the possibility to use primary refrigerants with reduced security. This communication presents the experimental results of the energy evaluation of an indirect cascade using CO2 as low temperature refrigerant and different refrigerants in the high temperature cycle (R-134a, R-152a, R-1234ze(E), R-290 and R-1270). The system serves a medium temperature cabinet and a low temperature island placed inside a climatic chamber under laboratory conditions. The evaluation covers three heat rejection levels (18.9, 31.8 and 42.3ºC).
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Alternative refrigerants for the primary circuit of an indirect commercial refrigeration cascade system.
- Identifiant de la fiche : 30023493
- Langues : Anglais
- Sujet : Alternatives aux HFC
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Date d'édition : 18/06/2018
- DOI : http://dx.doi.org/10.18462/iir.gl.2018.1126
Liens
Voir d'autres communications du même compte rendu (177)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFC;
CO2;
Hydrocarbures;
Supermarchés, meubles de vente - Mots-clés : Rejet de chaleur; Meuble de vente; Système indirect; Système en cascade; HFO; HFC; Experimentation; Frigorigène; CO2
-
Comportamiento energético de una instalación fr...
- Auteurs : SÁNCHEZ D., LLOPIS R., CATALÁN-GIL J., et al.
- Date : 19/06/2018
- Langues : Espagnol
- Source : CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
Voir la fiche
-
Refrigerating concept for small supermarkets us...
- Auteurs : HEERUP C.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF
Voir la fiche
-
Une cascade R404A/CO2 pour froid positif et nég...
- Auteurs : LE MERCIER P.
- Date : 03/2010
- Langues : Français
- Source : La revue pratique du froid et du conditionnement d'air - n. 983
Voir la fiche
-
Un nouveau système frigorifique pour un superma...
- Auteurs : NING J., PENG M., LI H.
- Date : 2006
- Langues : Chinois
- Source : Refrigeration - vol. 94 - n. 1
Voir la fiche
-
Chilling statistics.
- Auteurs : CAMPBELL A.
- Date : 08/2007
- Langues : Anglais
- Source : Build. Serv. J. - vol. 29 - n. 8
Voir la fiche