Gradients de concentration d'isobutane ou de propane dans des pièces lors de fuites.
Auteurs : CLODIC D.
Type d'article : Article
Résumé
These tests show that the practical limit of 8 g/m3 for propane and isobutane does not prevent concentrations near the floor being higher than the lower flammability limit for durations between 30 minutes and 1 hour 30 minutes. Phenomena of over-concentration at floor level appear systematically when there is a barrier near the floor, but also when leaks happen in room corners. In all cases, when leaks occur below 30 cm, the concentration horizontal gradient is significantly more uniform than the vertical gradient. With natural convection, durations in the range of 2 hours are necessary to return to a uniform concentration of propane in the test room and more than 5 hours with isobutane.
Détails
- Titre original : Gradients de concentration d'isobutane ou de propane dans des pièces lors de fuites.
- Identifiant de la fiche : 1999-0084
- Langues : Français
- Source : Kelvin - n. 3-4
- Date d'édition : 1997
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (12)
Voir la source
Indexation
-
Thèmes :
Circulation du fluide : tuyauterie, régulation, automatisme, sécurité;
Hydrocarbures;
Applications domestiques (réfrigérateurs, congélateurs);
Confinement, réduction de la charge en frigorigène - Mots-clés : Isobutane; Sécurité; Réfrigerateur domestique; Propane; Inflammabilité; Fuite; Frigorigène
-
Safety of appliances using hydrocarbon refriger...
- Auteurs : GTZ Proklima, COLBOURNE D.
- Date : 07/2008
- Langues : Anglais
Voir la fiche
-
Diffusion of flammables in rooms due to leaks f...
- Auteurs : CLODIC D.
- Date : 21/10/1996
- Langues : Anglais
Voir la fiche
-
Concentrations of hydrocarbon refrigerant exiti...
- Auteurs : COLBOURNE D., SUEN K. O.
- Date : 13/06/2022
- Langues : Anglais
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
Voir la fiche
-
Influence of leakage of natural non-azeotropic ...
- Auteurs : YAN J., YAN G., QIAN W., et al.
- Date : 05/04/2008
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR'2008.
Voir la fiche
-
General framework for revising class A3 refrige...
- Auteurs : COLBOURNE D., SUEN K. O., LI T. X., VONSILD A.
- Date : 09/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 117
- Formats : PDF
Voir la fiche