Part-load working influence on the seasonal performances of air conditioners.
Influenza del funzionamento a potenza ridotta sulle prestazioni stagionali di condizionatori d'aria.
Author(s) : SCHIBUOLA L.
Summary
The advantages of a correct prediction of the seasonal energy consumption of HVAC systems are multiple. First of all the capability to estimate the energy and economic cost of the management of these plants when confronted with different design options about the building-plant system. The performance of an HVAC system derives not only from the operative thermal levels, but also from the building requirement trend which normally involves frequent reduction of the full capacity. Nowadays, awareness of the importance of part-load working influence on the equipment efficiency is rising. The consequence is the introduction (Italian standard UNI 10963) or the modification of the standards used in testing the equipment under part-load conditions in order to better understand and quantify the part load influence. This paper presents the procedures and the results from their use for the simulation of the building-plant system in order to evaluate the long-term performances of split systems with on-off or modulating control.
Details
- Original title: Influenza del funzionamento a potenza ridotta sulle prestazioni stagionali di condizionatori d'aria.
- Record ID : 2006-1419
- Languages: Italian
- Subject: Regulation
- Source: Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
- Publication date: 2002/03/07
Links
See other articles from the proceedings (32)
See the conference proceedings
-
Calcolo delle prestazioni di unità di condizion...
- Author(s) : SCHIBUOLA L.
- Date : 2002/09
- Languages : Italian
- Source: Termotecnica - vol. 56 - n. 7
View record
-
Method of testing for rating room air condition...
- Date : 1998/03
- Languages : English
- Source: ASHRAE Stand. - BSR-ASHRAE 16-1983 (RA); 9 p.; 5 fig.; 2 tabl.; 3 ref.; append.
View record
-
Method of testing for rating room air condition...
- Author(s) : ASHRAE
- Date : 1999
- Languages : English
View record
-
Methods of testing for rating room fan-coil air...
- Date : 1991
- Languages : English
- Source: ASHRAE Stand. - ANSI-ASHRAE Stand. 79-1984 (RA 91); 14 p.; 10 fig.; 2 tabl.; 3 ref.
View record
-
Climatiseurs, groupes refroidisseurs de liquide...
- Date : 1997/10
- Languages : French
- Source: Norme eur./Norme fr. homol. AFNOR - NF EN 255-2/E 38-115-2; 14 p.; 5 tabl.; 4 ref.; 1 append.