Document IIF

Mécanisme de déversement et d'ébullition excessive de l'eau durant le refroidissement sous vide.

Mechanism of spillage and excessive boiling of water during vacuum cooling.

Auteurs : SONG X. Y., LIU B. L., JAGANATHAN G. K., et al.

Type d'article : Article, Article de la RIF

Résumé

Immersion vacuum cooling is a novel method for cooling meat products. This method has notable advantages including lower water loss rate of products during the cooling process. However, excessive solution boiling and spillage during immersion vacuum cooling process are considered as the serious problems limiting its wide-spread application. In this study, the mechanism of water boiling and spillage during vacuum cooling was studied by capturing the images of boiling phenomena with a high speed camera. Results show that the growth of bullet bubble is a major reason for more than 42% of water loss during boiling, because the diameter of a bullet bubble can increase to the diameter value of the test tube in 0.36 s. Our results also show that using moderate volumetric displacement of vacuum pump (for instance 0.0012 m3 s-1 in this paper) and controlling the chamber pressure in the range of 10–2 kPa can weaken the intensity of boiling and spillage of water. These results are discussed in the context of 'classical pool boiling' theory.

Documents disponibles

Format PDF

Pages : 37-42

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Mechanism of spillage and excessive boiling of water during vacuum cooling.
  • Identifiant de la fiche : 30014804
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 56
  • Date d'édition : 08/2015

Liens


Voir d'autres articles du même numéro (21)
Voir la source