Document IIF
Mesures en ligne de la concentration d'une solution aqueuse d'ammoniac.
On-line concentration measurement of ammonia aqueous solution.
Auteurs : JEONG S., YOON H. G., KIM D. H., et al.
Résumé
In this study, an on-line concentration measurement method for an ammonia/water solution is developed. Experiments for ammonia aqueous solution have been carried out for a concentration range of 25-45%. The result of the on-line method was compared with that of the extraction method which determines the concentration by measuring the density and the temperature of the extracted solution. The major findings in this study can be summarized as follows: 1) both methods showed quite good agreement (within 0.7%) regardless the concentration, circulation rate, and the heating/cooling power; 2) for all cases, the concentration measured by the extraction method is smaller than that measured by the on-line method. It is supposed that some of ammonia might be evaporated during the handling of the solution sample; and 3) with the measurement devices used in this study, the maximum errors in concentration of the solution (20-58%) induced by errors in pressure in temperature measurements are calculated to be 0.05 and 0.1%, respectively.
Documents disponibles
Format PDF
Pages : 237-243
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : On-line concentration measurement of ammonia aqueous solution.
- Identifiant de la fiche : 30001196
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Date d'édition : 06/04/2011
Liens
- Voir les traductions : Medición on-line de la concentración de la solución acuosa de amoniaco.
Voir d'autres communications du même compte rendu (122)
Voir le compte rendu de la conférence
Indexation
-
Medición on-line de la concentración de la solu...
- Auteurs : JEONG S., YOON H. G., KIM D. H., et al.
- Date : 04/2012
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 40 - n. 446
- Formats : PDF
Voir la fiche
-
Experimental analysis of a small-capacity ammon...
- Auteurs : ZOTTER G., RIEBERER R.
- Date : 02/03/2014
- Langues : Anglais
- Source : International sorption heat pump conference (ISHPC2014), College Park, United States, March 31-April 2, 2014.
- Formats : PDF
Voir la fiche
-
Experimental analysis of a novel concept of a “...
- Auteurs : ZOTTER G., RIEBERER R.
- Date : 12/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 60
- Formats : PDF
Voir la fiche
-
Thermodynamic analysis on an ammonia water abso...
- Auteurs : DU S., WANG R.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche
-
Performance analysis of ammonia absorption GAX ...
- Auteurs : PARK C. W., KOO J., KANG Y. T.
- Date : 06/2008
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 4
- Formats : PDF
Voir la fiche