Méthode de mesure du radon dans les réseaux d'égout résidentiels.
Method for radon measurement in residential sewer connections.
Numéro : pap. 3195
Auteurs : YUILL D.
Résumé
Radon gas is the most deadly indoor air pollutant. In the US, it is responsible for over 20,000 deaths per year. Residential exposure is typically the largest portion of a person’s annual exposure, so a great deal of research has been done to understand the pathways that radon can follow to enter a house. Since radon emanates from the ground, it is present in high concentration in soil gas. Recent research on the vapor intrusion of volatile organic compounds from subsurface sources into a test house concluded that the sewer line is an important preferential pathway. Despite the potential for high concentrations of radon in sewers, there have been no studies examining correlations between sewer concentrations and indoor concentrations. One reason may be that it is very difficult to measure radon concentrations in sewers. To address this problem, the author has developed a method for testing radon concentrations in residential sewer connections, and conducted case studies to test and refine the method. The method uses the sewer cleanout cap as an access point, and addresses the problem of condensation from hot water discharge into the sewer system by heating a sampling chamber that holds the radon sampling device. Preliminary results show a large variation in sewer radon concentrations temporally, two measured values showed 133.3 pCi/L (4930 Bq/m³) and 636 pCi/L (23,500 Bq/m³). For context, the US EPA recommends taking action if indoor levels are above 4 pCi/L (148 Bq/m³). Future work will examine correlations between indoor concentrations and sewer gas concentrations.
Documents disponibles
Format PDF
Pages : 7
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Method for radon measurement in residential sewer connections.
- Identifiant de la fiche : 30024745
- Langues : Anglais
- Source : 2018 Purdue Conferences. 5th International High Performance Buildings Conference at Purdue.
- Date d'édition : 09/07/2018
Liens
Voir d'autres communications du même compte rendu (88)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Domaines connexes au froid
- Mots-clés : Secteur résidentiel; Eau chaude; Gaz; Sécurité; Mesure; Radon; Santé; Condensation; Concentration
-
Economic analysis of a residential heating syst...
- Auteurs : XIA Y., TONG L., WANG L., et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Experimental drying characteristics of fabrics ...
- Auteurs : ASHER W. E., NAWAZ K., YANG C.-M., FRICKE B., BUYADGIE O.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
CFD research of the counter-flow spray concentr...
- Auteurs : YU J., JIN S.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Resenja zgrada za snabdevanje niskotemperaturne...
- Auteurs : GUDMUNDSSON O., THORSEN J. E., BRAND M.
- Date : 12/2016
- Langues : Anglais
- Source : 47th International HVAC&R Congress and Exhibition.
- Formats : PDF
Voir la fiche
-
Mogucnosti individualnog iskljucenja sa sistema...
- Auteurs : MITRIC M.
- Date : 12/2016
- Langues : Serbe
- Source : 47th International HVAC&R Congress and Exhibition.
- Formats : PDF
Voir la fiche