Nouveaux mélanges de frigorigènes azéotropiques et quasi-azéotropiques à pression élevée et à faible GWP.
New high pressure low-GWP azeotropic and near-azeotropic refrigerant blends.
Auteurs : COX N., MAZUR V., COLBOURNE D.
Résumé
This paper describes the latest findings of a project to identify azeotropic and near-azeotropic mixtures with a normal boiling point of between -40 and -80°C. The aim was to match the saturated pressure-temperature characteristics and refrigerating capacity of existing refrigerants within this range (such as R410A and R744), whilst achieving higher critical temperatures and - where relevant - lower triple point temperatures. Thus, the intended outcome is an extended range of applicability and an improvement in energy efficiency. Of a large number of potential combinations, three azeotropic and near-azeotropic mixtures have been selected, all formed from natural refrigerants or synthetic chemicals with a global warming potential of less than 150. These mixtures were subject to a variety of analyses, including thermodynamic, performance and safety assessments. Patents have been filed and published and global licensees are now being sought.
Documents disponibles
Format PDF
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : New high pressure low-GWP azeotropic and near-azeotropic refrigerant blends.
- Identifiant de la fiche : 2009-0025
- Langues : Anglais
- Source : 2008 Purdue Conferences. 19th International Compressor Engineering Conference at Purdue & 12th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Date d'édition : 14/07/2008
Liens
Voir d'autres communications du même compte rendu (125)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFC;
Ammoniac;
CO2;
Hydrocarbures;
Autres frigorigènes;
Mélanges - Mots-clés : R410A; R161; Propylène; Sécurité; Ammoniac; R41; R170; Performance; Mélange azéotropique; GWP; Frigorigène; CO2
-
Performance of a low-GWP near-azeotropic altern...
- Auteurs : COLBOURNE D., COX N., SUEN K. O., et al.
- Date : 07/09/2008
- Langues : Anglais
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF
Voir la fiche
-
Phase equilibria in low GWP azeotropic refriger...
- Auteurs : ARTEMENKO S., COX N., COULBORNE D., et al.
- Date : 23/06/2009
- Langues : Anglais
- Source : 3rd Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Equilibre de phase dans des mélanges d'ammoniac...
- Auteurs : ARTEMENKO S. V.
- Date : 2008
- Langues : Russe
- Source : Holodil'na Tehnika i Tehnologiâ - n. 5
Voir la fiche
-
Azeotropy in natural and artificial refrigerant...
- Auteurs : ARTEMENKO S., KHMEL'NJUK M., MAZUR V.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF
Voir la fiche
-
Performance of R170 mixtures as refrigerants fo...
- Auteurs : GONG M., SUN Z., WU J., et al.
- Date : 08/2009
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 5
- Formats : PDF
Voir la fiche