Document IIF
Performance d'une roue déshydratante affectée par l'isothermie.
Performance of desiccant wheel affected by isotherm.
Numéro : pap. ID171
Auteurs : FENG S. Y., DANG C. B., WANG Z. S., et al.
Résumé
The adsorption performance of a desiccant wheel directly determines the removed amount of the moisture from the air. With the demand of increasing COP, reducing the power consumption and lowering down the regeneration temperature, many kinds of new adsorbents are developed. The isotherm is the inherent property of adsorbents, and its shape will affect the adsorption capacity. Recently, it is deemed that Type S isotherm is one of the best shapes because at a wide range of the adsorption and desorption relative humidity, the saturation adsorption amount changes a little and it is easy to be reactivated. In the present study a mathematical model, in which the moisture transportation inside the sorbent layer is calculated by the Fick’s law, is set up, and the predication accuracy of the model is verified by the experimental data. Then, several kinds of hypothetical isotherms are manually offered and the adsorption performances of desiccant wheel using these isotherms are compared. The study result reveals that the Type S isotherm is not the most ideal isotherm when it is applied into the real desiccant wheel because the variation of the relative humidity of the air along the flow direction in the adsorption channels will lead to the desiccant wheel working at its worst range. Moreover, the linear type isotherm is always moderate.
Documents disponibles
Format PDF
Pages : 9 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance of desiccant wheel affected by isotherm.
- Identifiant de la fiche : 30012386
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Date d'édition : 02/08/2014
Liens
Voir d'autres communications du même compte rendu (119)
Voir le compte rendu de la conférence
-
Numerical simulation of rotary desiccant dehumi...
- Auteurs : JANI D. B., MISHRA M., SAHOO P. K.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Efficient configurations for desiccant wheel co...
- Auteurs : TU R., HWANG Y.
- Date : 02/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 86
- Formats : PDF
Voir la fiche
-
A mathematical model for predicting the perform...
- Auteurs : GE T. S., ZIEGLER F., WANG R. Z.
- Date : 06/2010
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 30 - n. 8-9
Voir la fiche
-
Simulation of heat driven air-conditioning syst...
- Auteurs : DE ANTONELLIS S., JOPPOLO C. M., MOLINAROLI L.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
Grey-box modelling and in situ experimental ide...
- Auteurs : APRILE M., MOTTA M.
- Date : 03/2013
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 51 - n. 1-2
Voir la fiche