Performance measurement of R32 in vapor injection heat pump system.
Numéro : pap. 2328
Auteurs : HWANG Y., RADERMACHER R., XU X.
Résumé
As global warming has raised more critical concerns in recent years, refrigerants with high global warming potentials (GWP) are facing the challenges of being phased out. R410A, with a GWP of 2,088, has been widely used in residential air-conditioning and heat pump systems. A potential substitute for R410A is R32, which has a GWP of 675. This paper investigates the performance difference of R410A and R32 in a vapor-injected heat pump system. A drop-in test was performed using R32 in a heat pump system that was designed for R410A, for both cooling and heating conditions. Through experimentation, it was found that for a single-stage cycle without vapor injection, the capacity improvement of using R32 was between 3.4% and 9.7%, and the COP improvement was between 2.0% and 9.0%, as compared to an identical cycle using R410A. For the vapor injection mode, the capacity improvement of R32 was found to be 1.8% to 7.4%, and the COP improvement was found to be 1.2% to 5.7%. No improvement was found for extreme cooling and heating conditions. High compressor discharge temperature was observed at extreme cooling and heating conditions when using R32. The compressor performance was analyzed to better understand the performance difference between the two different refrigerants. It is concluded that R32 is an excellent alternative to replace R410A in terms of performance and can be further enhanced by component optimization.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance measurement of R32 in vapor injection heat pump system.
- Identifiant de la fiche : 30006215
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 16/07/2012
Liens
Voir d'autres communications du même compte rendu (195)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
HFC;
Efficacité energétique, économie d'énergie - Mots-clés : R410A; Mesure; Vapeur; R32; Substitut; Pompe à chaleur; Performance; Injection
-
Steady state and transient validation of heat p...
- Auteurs : BHANOT V., BACELLAR D., LING J., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Performance comparison of R410A and R32 in vapo...
- Auteurs : HWANG Y., RADERMACHER R., XU X.
- Date : 05/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 3
- Formats : PDF
Voir la fiche
-
Testing, simulation and soft-optimization of R4...
- Auteurs : ALABDULKAREM A., ELDEEB R., HWANG Y., et al.
- Date : 12/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 60
- Formats : PDF
Voir la fiche
-
Effects of flash and vapor injection on the air...
- Auteurs : JANG Y., LEE E., CHIN S., et al.
- Date : 12/07/2010
- Langues : Anglais
- Source : 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Effects of intermediate pressure on the heating...
- Auteurs : ROH C. W., KIM M. S.
- Date : 12/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 8
- Formats : PDF
Voir la fiche