Mesure de la performance du R32 dans un système de pompe à chaleur à injection de vapeur.
Performance measurement of R32 in vapor injection heat pump system.
Number: pap. 2328
Author(s) : HWANG Y., RADERMACHER R., XU X.
Summary
As global warming has raised more critical concerns in recent years, refrigerants with high global warming potentials (GWP) are facing the challenges of being phased out. R410A, with a GWP of 2,088, has been widely used in residential air-conditioning and heat pump systems. A potential substitute for R410A is R32, which has a GWP of 675. This paper investigates the performance difference of R410A and R32 in a vapor-injected heat pump system. A drop-in test was performed using R32 in a heat pump system that was designed for R410A, for both cooling and heating conditions. Through experimentation, it was found that for a single-stage cycle without vapor injection, the capacity improvement of using R32 was between 3.4% and 9.7%, and the COP improvement was between 2.0% and 9.0%, as compared to an identical cycle using R410A. For the vapor injection mode, the capacity improvement of R32 was found to be 1.8% to 7.4%, and the COP improvement was found to be 1.2% to 5.7%. No improvement was found for extreme cooling and heating conditions. High compressor discharge temperature was observed at extreme cooling and heating conditions when using R32. The compressor performance was analyzed to better understand the performance difference between the two different refrigerants. It is concluded that R32 is an excellent alternative to replace R410A in terms of performance and can be further enhanced by component optimization.
Available documents
Format PDF
Pages: 10 p.
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Performance measurement of R32 in vapor injection heat pump system.
- Record ID : 30006215
- Languages: English
- Source: 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Publication date: 2012/07/16
Links
See other articles from the proceedings (195)
See the conference proceedings
Indexing
-
Themes:
Heat pumps techniques;
HFCs;
Energy efficiency, energy savings - Keywords: R410A; Measurement; Vapour; R32; Substitute; Heat pump; Performance; Injection
-
Performance comparison of R410A and R32 in vapo...
- Author(s) : HWANG Y., RADERMACHER R., XU X.
- Date : 2013/05
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 3
- Formats : PDF
View record
-
Effects of intermediate pressure on the heating...
- Author(s) : ROH C. W., KIM M. S.
- Date : 2011/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 8
- Formats : PDF
View record
-
Performance investigation of two-stage heat pum...
- Author(s) : WANG Y., YE Z., CAO F.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Drop in life cycle climate performance of low G...
- Author(s) : LI G., ALABDULKAREM A., HWANG Y., et al.
- Date : 2014/08/02
- Languages : English
- Source: 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
View record
-
Nytt på köldmediefronten: alternativa köldmedie...
- Author(s) : MAKHNATCH P., KHODABANDEH R., PALM B.
- Date : 2012
- Languages : Swedish
- Source: KYLA+ Värmepumpar - n. 6
View record