Recherche sur les facteurs d’influence des camions frigorifiques transportant des vaccins.

Research on influencing factors of vaccine refrigerated truck.

Numéro : 1042

Auteurs : FENG X., ZHANG Z., JING H., GAO E., ZHANG X., HUA X.

Résumé

This paper focuses on a 3.9 m3 2~8℃ vaccine refrigerated truck, conducting experimental tests to investigate the impact of solar radiation intensity and a strip curtain on its temperature distribution. The
analysis incorporates evaluation indexes to assess the uniformity of temperature and the rate of temperature change during the measurement period. The results show that after the vaccine refrigerated
truck was placed under the conditions of average solar radiation intensity of 576W×m-2 and 83W×m-2 for 2 hours respectively, the average temperature in the former refrigerated truck was 1.326℃ higher than that of the latter. Equipped with a strip curtain, it can effectively prevent the cold air in the refrigerated truck from escaping to the outside environment. Even in the case of opening the truck door, it can minimize
temperature fluctuations inside the refrigerated truck.

Documents disponibles

Format PDF

Pages : 8 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Research on influencing factors of vaccine refrigerated truck.
  • Identifiant de la fiche : 30032543
  • Langues : Anglais
  • Sujet : Technologie
  • Source : 8th IIR International Conference on Sustainability and the Cold Chain. Proceedings: June 9-11 2024
  • Date d'édition : 11/06/2024
  • DOI : http://dx.doi.org/10.18462/iir.iccc2024.1042