Document IIF

Visualisation de la distribution de la température dans un tube frigorifique thermoacoustique.

Visualization of the temperature distribution in a thermoacoustic refrigeration tube.

Résumé

Visualization of the temperature distribution in a thermoacoustic refrigeration tube and some measurements of the flow rate of outlet air were examined experimentally. The following results were obtained: the cooled air blew out naturally from the outlet hole of the thermoacoustic tube; the temperature of the outlet air was shown to be cooled by measurement and visualization; the flow rate of outlet air increased with the increase of the electric input power to the acoustic speaker and the increase of the diameter of the outlet hole; the temperature difference of the outlet air decreased with the increase in the flow rate of the outlet air.

Documents disponibles

Format PDF

Pages : 2002-5

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Visualization of the temperature distribution in a thermoacoustic refrigeration tube.
  • Identifiant de la fiche : 2004-0715
  • Langues : Anglais
  • Date d'édition : 17/09/2002
  • Source : Source : Proc. 5th IIR-Gustav Lorentzen Conf. nat. Working Fluids, Guangzhou/C. R. Conf. Guangzhou, IIF
    2002-5; sess. 4; pap. 54; 427-435; fig.; 7 ref.