Recommandé par l'IIF / Document IIF
Caractérisation expérimentale de la réponse à la demande dans une chambre froide.
Experimental characterization of demand response in a refrigerated cold room.
Auteurs : AKERMA M., HOANG H. M., LEDUCQ D., DELAHAYE A.
Type d'article : Article de la RIF
Résumé
Demand response (DR) is one of the energy management strategies that can relieve the strain on power grid by balancing the energy consumption and production. Cold storage in warehouses and cold rooms, due to the high thermal inertia contained in the stored products, is a promising solution for applying DR. For cooling applications, different DR strategies can be considered: stopping evaporator fans or stopping the refrigeration machine, producing more cooling power during off peak hours and reducing the cooling operation during on peak hours, etc. However, these scenarios need to be carefully applied to respect the temperature regulation in order to maintain food quality and security. Moreover, DR application might lead to an increase of power demand when restarting the cold machine – the postponing power effect or an over-consumption of energy for the recovery of the temperature level before DR – the postponing consumption effect. This paper presents an experimental investigation of DR application in a loaded cold room; the impact of several DR parameters: product load, outside temperature, set point temperature and DR duration were assessed. The results showed that DR has limited impact on the stored product: a maximum increase of 1.1 °C at the product core after 3 days of DR application, one DR per day. However, a cumulative effect of DR applications on product temperature was observed. The indicators of the postponing power effect and consumption variation showed important impacts of studied parameters on the system behaviour during DR application.
Documents disponibles
Format PDF
Pages : 256-265
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental characterization of demand response in a refrigerated cold room.
- Identifiant de la fiche : 30027433
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 113
- Date d'édition : 05/2020
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.02.006
Liens
Voir d'autres articles du même numéro (28)
Voir la source
-
LA CHAINE DU FROID ET LES PROBLEMES DE REGULATION.
- Auteurs : ALONSO M.
- Date : 01/1984
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 12 - n. 135
Voir la fiche
-
MESURES DE PROTECTION DANS LES ENTREPOTS FRIGOR...
- Auteurs : SIMONCIC J.
- Date : 1984
- Langues : Serbo-croate
- Source : Zast. Radnika Radu - vol. 14 - n. 6
Voir la fiche
-
OUTILS ET METHODES LOGISTIQUES DANS LES ACTIVIT...
- Auteurs : MILLOT M., HAROCH M.
- Date : 1989
- Langues : Français
- Source : Rev. gén. Froid - vol. 79 - n. 10
Voir la fiche
-
Distributing to the retailer.
- Date : 09/2010
- Langues : Anglais
- Source : Air Conditioning and Refrigeration Journal, Cold Chain - vol. 24 - n. 5
- Formats : PDF
Voir la fiche
-
LA LIVRAISON: MAILLON FINAL DE LA CHAINE DU FROID.
- Auteurs : RAGAZZI G.
- Date : 1981
- Langues : Italien
- Source : Industria italiana del Freddo - vol. 35 - n. 2
Voir la fiche