Comment racler la glace pour réduire et éliminer l'encrassement, afin de réaliser un nettoyage in situ.
Ice-pigging to reduce and remove fouling and to achieve clean-in-place.
Auteurs : QUARINI J.
Type d'article : Article
Résumé
Experimental and theoretical work has been undertaken to investigate the clean-in-place, CIP, and fouling removal capability of a novel patented crushed ice pigging system. The "pig" consists of crushed ice in water with a freezing point depressant. The void fraction is carefully controlled so that the ice/water mix moves like a solid plug in free flow areas, but is able to flow like a fluid in constricted areas. The ice pig is able to flow in pipes with sharp bends, through orifice plates, through T's and even in plate heat exchangers. The experimental work evaluating the "cleaning efficiency" of this system indicated that the ice pig could easily and efficiently remove "soft" fouling.
Détails
- Titre original : Ice-pigging to reduce and remove fouling and to achieve clean-in-place.
- Identifiant de la fiche : 2002-3202
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 22 - n. 7
- Date d'édition : 04/2002
Liens
Voir d'autres articles du même numéro (8)
Voir la source
Indexation
- Thèmes : Autres applications industrielles
- Mots-clés : Coulis de glace; Industrie alimentaire; Tuyauterie; Procédé; Nettoyage
-
Technologia czyszczenia strumieniem czastek suc...
- Auteurs : WITKOWSKI A.
- Date : 12/2005
- Langues : Polonais
- Source : Przemysl Spozywczy - vol. 59 - n. 12
Voir la fiche
-
Ice fraction measurement of ice slurries throug...
- Auteurs : HALES A., QUARINI G., ASH D., et al.
- Date : 11/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 47
- Formats : PDF
Voir la fiche
-
Estudio comparativo de varios métodos de valora...
- Auteurs : VALCÁRCEL S., ESCUDERO J. M., MARCO J. M.
- Date : 2002
- Langues : Espagnol
- Source : Acta Alimentaria - vol. 39 - n. 335
Voir la fiche
-
Alimentation en eau glacée utilisant un coulis ...
- Auteurs : MITO D., MANO T., TANINO M., et al.
- Date : 2013
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 30 - n. 3
Voir la fiche
-
Internal coil flushing: quick, easy, and effect...
- Auteurs : SYMONDS S.
- Date : 30/03/1998
- Langues : Anglais
- Source : Air Cond. Heat. Refrig. News - vol. 203 - n. 13
Voir la fiche