Effet de la réduction de la vitesse du ventilateur sur les durées de congélation et la consommation d'énergie d'un tunnel de congélation.

Efecto de une velocidad reducida del ventilador de aire sobre los tiempos de congelación y el consumo de energía en un túnel de congelación.

Auteurs : WIDELL K. N., EIKEVIK T. M., WALNUM H. T.

Type d'article : Article

Résumé

Large ammonia refrigeration systems are commonly used by Norway's fish freezing industry. While the energy efficiency of these systems varies, it has improved in recent years but can continue to benefit from improvements. Air blast freezing tunnels are used to freeze large numbers of fish. Typically, a batch tunnel is filled, the refrigeration system and air fans are started and run uninterrupted until the freezing tunnel is unloaded after 20 h. The refrigeration load from the product falls as the product temperature drops, but the fans often run at full speed during the entire freezing period, which results in a constant heat load to the freezing tunnel. This paper examines the efficiencies that result from reducing the fan speed after a certain time. A simulation program was developed to test different operation modes. It calculated the product temperatures in the tunnel and the electricity demand by the refrigeration system and the air fans. The air velocity field inside the freezing tunnel varied with location, which resulted in different product freezing times. The results show a reduction of 73% in total energy consumption compared to the baseline case when the freezing time was extended to 29.2 h and the fan speed was reduced to 33% after 8 h. Reductions in air temperatures (2 and 4°C) during the second part of the freezing period could decrease the total freezing time, but the net effect on energy consumption depends on the rest of the refrigeration system.

Documents disponibles

Format PDF

Pages : 20-27 (7 p.)

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Efecto de une velocidad reducida del ventilador de aire sobre los tiempos de congelación y el consumo de energía en un túnel de congelación.
  • Identifiant de la fiche : 30011698
  • Langues : Espagnol
  • Source : Frío Calor Aire acondicionado - vol. 42 - n. 469
  • Date d'édition : 05/2014

Liens


Voir d'autres articles du même numéro (1)
Voir la source