Document IIF
Study on method ensuring safety of built-in refrigerated display cabinet using R290.
Étude d’une méthode assurant la sécurité d’un meuble frigorifique de vente intégré utilisant le R290.
Numéro : pap. n. 337
Auteurs : YAMASHITA K., SAKAMOTO Y., KATO T., et al.
Résumé
In Japan, from 2011 to 2016, risk assessment of each type of equipment using A2L refrigerant was carried out and JRAIA standard which prescribed safe operating method was created, resulting in the relaxation of law was realized. In order to respond to demand in recent years to further lower GWP, risk assessment of built-in refrigerated display cabinet using R290 was carried out. CFD analyses on refrigerant leakage from inside or outside the refrigerated space of each type of refrigerated display cabinet was carried out, flammable volume was calculated, potential ignition sources were investigated, and ignition probability was calculated. Risk assessments were carried out at each stage of transportation, storage, installation, usage, service, and disposal. In this paper, the contents of the study and the safety operation method created as a result are summarized.
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Study on method ensuring safety of built-in refrigerated display cabinet using R290.
- Identifiant de la fiche : 30026407
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Date d'édition : 24/08/2019
- DOI : http://dx.doi.org/10.18462/iir.icr.2019.0337
Liens
Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence
Indexation
-
Ignition sources at the stage of usage for mini...
- Auteurs : TAMURA K., TAKAICHI K., TAIRA S., BABA A., ITAKURA S., MORI H., MAKINO H.
- Date : 07/12/2020
- Langues : Anglais
- Source : 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants(GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
Voir la fiche
-
A3 refrigerant R290 leak and ignition testing f...
- Auteurs : WANG X.
- Date : 26/08/2020
- Langues : Anglais
- Source : 6th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Nantes, France, August 26-28 2020
- Formats : Vidéo, PDF
Voir la fiche
-
R290 concentrations arising from leaks in comme...
- Auteurs : COLBOURNE D., SUEN K. O.
- Date : 21/08/2016
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
Voir la fiche
-
Study on CFD analysis of refrigerant leakage an...
- Auteurs : YAMASHITA K., SAKAMOTO Y., KATO T., et al.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche
-
General framework for revising class A3 refrige...
- Auteurs : COLBOURNE D., SUEN K. O., LI T. X., VONSILD A.
- Date : 09/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 117
- Formats : PDF
Voir la fiche