Document IIF
Le CO2 utilisé comme frigorigène dans les congélateurs à plaques existants.
CO2 as refrigerant in new and existing plate freezers.
Auteurs : HANSEN T. M., CHRISTENSEN K. G., MINDS G., et al.
Résumé
A comparative analysis of CO2, ammonia and HFC-404A as refrigerants in plate freezers has been carried out. The results reveal that CO2, apart from offering an environmentally sound solution (locally and globally), also provide an improved operation of freezing equipment. The heat transfer coefficients are improved, the effective temperature loss due to pressure drop is less, energy consumption can be lowered, the evaporation temperature can be lowered to -55 °C and due to very high gas densities, the pressure losses in the system are significantly lower. On the other hand, one has to deal with a higher pressure on the low temperature side during defrosting and stand still. The paper describes the benefits that can be obtained with respect to improved freezing time and improved freezing capacity in self-contained plate freezer units and in pump circulated systems. Pressure drop, heat transfer, energy consumption as well as plate stress are evaluated in existing plate freezer systems retrofitted with CO2 and compared to ammonia and R404A. Alternative layouts and requirements to be met by the refrigeration plant due to the high pressure in new and existing freezing equipment are addressed.
Documents disponibles
Format PDF
Pages : 2001-1
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : CO2 as refrigerant in new and existing plate freezers.
- Identifiant de la fiche : 2005-1276
- Langues : Anglais
- Source : Rapid Cooling of Food.
- Date d'édition : 28/03/2001
Liens
- Voir les traductions : Utilizzo della CO2 come refrigerante in congelatori a piastre nuovi e già in esercizio.
Voir d'autres communications du même compte rendu (41)
Voir le compte rendu de la conférence
Indexation
-
Utilizzo della CO2 come refrigerante in congela...
- Auteurs : HANSEN T. M., CHRISTENSEN K. G., MINDS G., et al.
- Date : 2004
- Langues : Italien
- Source : IIF-IIR/Ind. Form. - vol. 28 - n. 6 (280)
Voir la fiche
-
PREDICTING TEMPERATURE VS TIME BEHAVIOUR DURING...
- Auteurs : RUBIOLO DE REINICK A., SCHWARTZBERG H.
- Date : 1986
- Langues : Anglais
- Source : Biotechnol. Prog. - vol. 2 - n. 3
Voir la fiche
-
Ammonia refrigeration system with CO2 as a seco...
- Auteurs : ONO M., KAWAMURA K., MUGABI N.
- Date : 06/05/2005
- Langues : Anglais
- Source : Ammonia Refrigerating Systems, Renewal and Improvement.
- Formats : PDF
Voir la fiche
-
Prévision numérique du temps de congélation des...
- Auteurs : LIO M.
- Date : 1993
- Langues : Chinois
- Source : Journal of Refrigeration - n. 4
Voir la fiche
-
NOUVELLES POSSIBILITES DE DETERMINATION DE LA T...
- Auteurs : FIKIIN K. A.
- Date : 09/1991
- Langues : Français
- Source : Rev. gén. Froid - vol. 81 - n. 7
Voir la fiche