Optimisation de la performance des systèmes d'aération verticaux.
Optimising the performance of vertical aeration systems.
Auteurs : BARTLETT D., ARMITAGE D. M., HARRAL B.
Résumé
Complex computational modelling of airflow from vertical aeration systems shows that if the aerator fan is set to blow rather than suck, then the volume of grain cooled is up to 20% greater and better cooling is obtained near the floor. Temperature, grain moisture content change and ventilating air pressure are measured in six commercial grain stores equipped with vertical ventilation systems. At each, the volume of air moved by the fan is up to 20% more when it is blowing than when it is sucking. A simple model, based on cooling front velocities and the pressure and flow characteristics obtained from the farm tests and trials with ducts, is developed to enable routine design of new systems in a short time. The simple model is compared with the complex model and good agreement demonstrated.
Détails
- Titre original : Optimising the performance of vertical aeration systems.
- Identifiant de la fiche : 2006-3016
- Langues : Anglais
- Source : Advances in stored product protection. Proceedings of the 8th International Working Conference on Stored Product Protection.
- Date d'édition : 22/07/2002
Liens
Voir d'autres communications du même compte rendu (14)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Ingénierie alimentaire;
Transfert de masse;
Graines et plantes - Mots-clés : Céréale; Ventilation; Air; Stockage; Modélisation; Distribution
-
A two-dimensional model of grain storage with d...
- Auteurs : XANTHOPOULOS G., WOODS J. L.
- Date : 22/07/2002
- Langues : Anglais
- Source : Advances in stored product protection. Proceedings of the 8th International Working Conference on Stored Product Protection.
Voir la fiche
-
Effect of suboptimal temperatures and sublethal...
- Auteurs : HULASARE R. B., WHITE N. D. G., JAYAS D. S.
- Date : 22/07/2002
- Langues : Anglais
- Source : Advances in stored product protection. Proceedings of the 8th International Working Conference on Stored Product Protection.
Voir la fiche
-
A three-dimensional control volume approach to ...
- Auteurs : RANJAN R., IRUDAYARAJ J., JUN S.
- Date : 2001
- Langues : Anglais
- Source : Trans. ASAE - vol. 44 - n. 6
Voir la fiche
-
Modelo físico predictivo de la dinámica climáti...
- Auteurs : LUKASSE L. J. S., KRAMER-CUPPEN J. E. de, VOORT A. J. van der
- Date : 04/2007
- Langues : Espagnol
- Source : IIF-IIR/Frío Calor Aire acond. - vol. 35 - n. 391
- Formats : PDF
Voir la fiche
-
Traitement par le froid du blé, en trois étapes.
- Auteurs : KALCHEV P., BALDZHIEV D., BEROVA S.
- Date : 1991
- Langues : Bulgare
- Source : Sci. Works - vol. 38 - n. 1
Voir la fiche