Document IIF
Prévisions concernant l'écoulement au niveau du panneau arrière d'un meuble frigorifique de vente grâce à la mécanique numérique des fluides.
CFD predictions of rear panel flow in a refrigerated display cabinet.
Numéro : pap. ID: 732
Auteurs : BARVE S., FOSTER A. M., EVANS J. A.
Résumé
The energy efficiency of open fronted multi-deck cabinets is highly related to the effectiveness of the cabinet air curtain and the efficiency of air distributed from the cabinet rear back panel. The correct proportion of air coming out of the air curtain and rear panel is important to maintain temperature performance and keep energy consumption low. Computational fluid dynamics (CFD) is a useful tool to examine the influence of the rear panel/discharge air ratio on the optimum function of the cabinet. One of the primary problems with CFD modelling is to know the boundary conditions of the model. CFD models often assume that rear panel flow is evenly distributed across the whole panel and that changes in overall flow rate do not change the proportion of flow exiting the back panel. In this paper the actual flow rate through the rear panel at different heights was predicted and compared to measured values. The predicted proportion of flow through the back panel was investigated as the total air mass-flow rate was varied.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : CFD predictions of rear panel flow in a refrigerated display cabinet.
- Identifiant de la fiche : 30002166
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Date d'édition : 21/08/2011
Liens
Voir d'autres communications du même compte rendu (569)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Supermarchés, meubles de vente
- Mots-clés : Meuble ouvert; CFD; Meuble de vente; Température; Rideau d'air; Prévision; Performance; Écoulement
-
Application of two-fluid model to the simulatio...
- Auteurs : YU K., CHEN T., DING G.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Open vertical cabinet (multi-deck) with sequent...
- Auteurs : SCHUSTER M., KRIEGER T.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
The design considerations of single-band air cu...
- Auteurs : CHEN Y., YUAN X.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Development of a design tool for recirculated a...
- Auteurs : HAMMOND E., EVANS J., FOSTER A.
- Date : 29/03/2010
- Langues : Anglais
- Source : 1st IIR International Conference on Sustainability and the Cold Chain
- Formats : PDF
Voir la fiche
-
Experimental quantitative evaluation of thermal...
- Auteurs : NASCIMENTO S. M., HEIDINGER G. G., GASPAR P. D.
- Date : 02/04/2013
- Langues : Anglais
- Source : 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
Voir la fiche