Document IIF
Un surgélateur à air pulsé utilisant le CO2 comme frigorigène.
A multi-chamber blast freezer with carbon dioxide as refrigerant.
Auteurs : PEARSON A.
Résumé
A recent industrial installation demonstrates the benefit of using carbon dioxide as a refrigerant in a low temperature blast freezer plant. This paper describes the freezer plant and presents performance information from operating experience. Freezing times have been reduced in comparison to expected performance and the plant operates more efficiently. The paper describes the performance expected of a conventional blast freezer system and suggests reasons why the carbon dioxide system performance exceeds expectations, with reference to evaporator design, plant configuration, suction line pressure losses and transient response to step changes in load. Design guidance for optimal performance is given, and the implications for other types of freezer plant are explained.
Documents disponibles
Format PDF
Pages : 2008-2
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A multi-chamber blast freezer with carbon dioxide as refrigerant.
- Identifiant de la fiche : 2009-0258
- Langues : Anglais
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Date d'édition : 07/09/2008
Liens
Voir d'autres communications du même compte rendu (132)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HCFC;
Installations de congélation;
CO2 - Mots-clés : Chambre froide; Conception; Recommandation; R22; Substitut; Performance; Étude de cas; Congélation; Frigorigène; Congélateur; CO2
-
Opportunities of R-22 phase out in different ap...
- Auteurs : LAMB R.
- Date : 29/11/2007
- Langues : Anglais
- Source : Carbon footprint: one step beyond. The IOR 2007 Annual Conference [CD-ROM].
Voir la fiche
-
Remplacement du R-22 : le compte à rebours a co...
- Date : 09/2007
- Langues : Français
- Source : Fluides Infos - vol. 17 - n. 42
Voir la fiche
-
Field tests using R404A in storage refrigeration.
- Auteurs : GIRAUD A., BARREAU M.
- Date : 1999
- Langues : Anglais
- Source : Refrigerated Transport, Storage and Retail Display.
- Formats : PDF
Voir la fiche
-
Options to replace R22.
- Auteurs : FLOHR F., MEURER C.
- Date : 02/09/2009
- Langues : Anglais
- Source : Compressors 2009: 7th International Conference on Compressors and Coolants
- Formats : PDF
Voir la fiche
-
Schneller R-22-Ersatz mit R-422D.
- Auteurs : KRÖGER J.
- Date : 11/2007
- Langues : Allemand
- Source : Kälte + Klimatechnik (Die) - vol. 60 - n. 11
Voir la fiche