Utilisation d'une association ammoniac-CO2-eau dans les meubles frigorifiques pour supermarchés.
Anvendelse af ammonia-CO2-water til køle-/frysemøbler i supermarkeder.
Auteurs : KAUFFELD M.
Résumé
Many parallel-coupled refrigeration installations presently installed in supermarkets are using R134a or R404A. Due to the use of chemical refrigerants with a relatively high greenhouse effect, the parallel-coupled plants will probably not be seen as environment-friendly in the future. A possible solution could be a combination of ammonia as refrigerant in the machine room and cooling distribution using evaporating CO2 or melting eutectics. Preliminary calculations show that plants of this kind are able to compete with actual parallel coupled installations seen both from the energy consumption and running costs points of view. The use of ice/water mixtures enables to further enhance economical benefits by cold accumulation. The author concludes that there are good possibilities to establish refrigeration installations for supermarkets using natural refrigerants.
Détails
- Titre original : Anvendelse af ammonia-CO2-water til køle-/frysemøbler i supermarkeder.
- Identifiant de la fiche : 1998-2904
- Langues : Danois
- Source : Dansk koledag '95.
- Date d'édition : 09/03/1995
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (4)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Supermarchés, meubles de vente
- Mots-clés : Caloporteur diphasique; Caloporteur; Eutectique; Ammoniac; Supermarché; Installation frigorifique; Frigorigène; CO2
-
Commercial refrigeration with ammonia and CO2 a...
- Auteurs : IEA HPC, EGGEN G., ROSVIK S.
- Date : 16/10/1995
- Langues : Anglais
- Source : Compression systems with natural working fluids. Applications, experience and developments. Workshop proceedings.
Voir la fiche
-
Secondary-loop refrigeration systems using ammo...
- Auteurs : INLOW S. W., GROLL E. A.
- Date : 02/10/1996
- Langues : Anglais
- Source : New Developments in Refrigeration for Food Safety and Quality.
- Formats : PDF
Voir la fiche
-
Pourquoi utiliser de l'ammoniac dans les grande...
- Auteurs : RIVET P.
- Date : 05/1996
- Langues : Français
- Source : La revue pratique du froid et du conditionnement d'air - n. 835
Voir la fiche
-
Investigation of ammonia-secondary fluid system...
- Auteurs : MCDOWELL T. P., MITCHELL J. W., KLEIN S. A.
- Date : 24/06/1995
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche
-
CO2 and ammonia in the supermarket Ica-Focus.
- Auteurs : ROLFSMAN L.
- Date : 03/09/1996
- Langues : Anglais
- Source : Applications for Natural Refrigerants
- Formats : PDF
Voir la fiche