Use of ammonia-CO2-water in refrigerated display cases for supermarkets.
Anvendelse af ammonia-CO2-water til køle-/frysemøbler i supermarkeder.
Author(s) : KAUFFELD M.
Summary
Many parallel-coupled refrigeration installations presently installed in supermarkets are using R134a or R404A. Due to the use of chemical refrigerants with a relatively high greenhouse effect, the parallel-coupled plants will probably not be seen as environment-friendly in the future. A possible solution could be a combination of ammonia as refrigerant in the machine room and cooling distribution using evaporating CO2 or melting eutectics. Preliminary calculations show that plants of this kind are able to compete with actual parallel coupled installations seen both from the energy consumption and running costs points of view. The use of ice/water mixtures enables to further enhance economical benefits by cold accumulation. The author concludes that there are good possibilities to establish refrigeration installations for supermarkets using natural refrigerants.
Details
- Original title: Anvendelse af ammonia-CO2-water til køle-/frysemøbler i supermarkeder.
- Record ID : 1998-2904
- Languages: Danish
- Source: Dansk koledag '95.
- Publication date: 1995/03/09
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (4)
See the conference proceedings
Indexing
- Themes: Supermarkets, display cabinets
- Keywords: Two-phase heat carrier; Heat carrier; Eutectic; Ammonia; Supermarket; Refrigerating plant; Refrigerant; CO2
-
CO2 and ammonia in the supermarket Ica-Focus.
- Author(s) : ROLFSMAN L.
- Date : 1996/09/03
- Languages : English
- Source: Applications for Natural Refrigerants
- Formats : PDF
View record
-
Commercial refrigeration with ammonia and CO2 a...
- Author(s) : IEA HPC, EGGEN G., ROSVIK S.
- Date : 1995/10/16
- Languages : English
- Source: Compression systems with natural working fluids. Applications, experience and developments. Workshop proceedings.
View record
-
Secondary-loop refrigeration systems using ammo...
- Author(s) : INLOW S. W., GROLL E. A.
- Date : 1996/10/02
- Languages : English
- Source: New Developments in Refrigeration for Food Safety and Quality.
- Formats : PDF
View record
-
Pourquoi utiliser de l'ammoniac dans les grande...
- Author(s) : RIVET P.
- Date : 1996/05
- Languages : French
- Source: La revue pratique du froid et du conditionnement d'air - n. 835
View record
-
Investigation of ammonia-secondary fluid system...
- Author(s) : MCDOWELL T. P., MITCHELL J. W., KLEIN S. A.
- Date : 1995/06/24
- Languages : English
- Source: ASHRAE Transactions.
View record