A criterion based on independent parameters for distinguishing departure from nucleate boiling and dryout in water cooled systems.
Author(s) : LOMBARDI C., MAZZOLA A.
Type of article: Article
Summary
The paper outlines the neural network methodology in order to identify the parameters which most influence the physical phenomenon under investigation. The results seem to demonstrate the possibility of distinguishing departure from nucleate boiling from dryout on the basis of inlet parameters.
Details
- Original title: A criterion based on independent parameters for distinguishing departure from nucleate boiling and dryout in water cooled systems.
- Record ID : 1998-2759
- Languages: English
- Source: Rev. gén. Therm. - vol. 37 - n. 1
- Publication date: 1998/01
Links
See the source
Indexing
- Themes: Mass transfer
- Keywords: Nuclear engineering; Measurement; Heat transfer; Surface; Drying; Heat flux; Critical flux; Detection; Nucleate boiling
-
A nucleate boiling limitation model for the pre...
- Author(s) : CHUNG H. J., NO H. C.
- Date : 2007/07
- Languages : English
- Source: International Journal of Heat and Mass Transfer - vol. 50 - n. 15-16
View record
-
STUDY OF HEAT TRANSFER AND CRITICAL THERMAL FLU...
- Author(s) : LEVTEROV A. I., SEMENA M. G., ZARIPOV V. K.
- Date : 1982
- Languages : Russian
- Source: Teploenergetika - n. 4
View record
-
Pool boiling heat transfer on thin wire in nitr...
- Author(s) : AMANO T.
- Date : 1992
- Languages : English
- Source: Heat Transf., Jap. Res. - vol. 21 - n. 8
View record
-
Transient boiling from inclined and downward-fa...
- Author(s) : GENK M. S. el-, GUO Z.
- Date : 1993/11
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 16 - n. 6
- Formats : PDF
View record
-
On the role of Marangoni effects on the critica...
- Author(s) : MCGILLIS W. R., CAREY V. P.
- Date : 1996/02
- Languages : English
- Source: J. Heat Transf. - vol. 118 - n. 1
View record