Accelerated evaluation of capillary clogging in HFC air conditioners.
Author(s) : TAIRA S., OONUMA Y., YAMAKAWA K., YAJIMA R.
Summary
The paper focuses on the accelerated evaluation method of capillary clogging and the methods to prevent HFC air conditioners from clogging. The clogging phenomenon is divided into four stages. First, the sludge is produced inside a compressor. Then, it is conveyed by lubricant to the capillaries or expansion valves. After it is separated from the refrigerants, it is deposited on the inner surfaces. The acceleration test was carried out by increasing the lubricant temperature and the refrigerant flow with different lubricants and compressors.
Details
- Original title: Accelerated evaluation of capillary clogging in HFC air conditioners.
- Record ID : 1999-3572
- Languages: English
- Source: Proceedings of the 1998 Purdue International Refrigeration Conference.
- Publication date: 1998/07/14
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (67)
See the conference proceedings
Indexing
- Themes: Supermarkets, display cabinets
- Keywords: Refrigerating circuit; Capillary; Measurement; Air conditioner; Fouling
-
Constitutive equations for capillary tube model...
- Author(s) : MELO C., NETO C. B., FERREIRA R. T. S., PEREIRA R. H.
- Date : 1998/07/14
- Languages : English
- Source: Proceedings of the 1998 Purdue International Refrigeration Conference.
View record
-
Simulation of the effects of oil in capillary t...
- Author(s) : SILVA HUERTA A. A., MATTOS SILVARES O. de
- Date : 1998/07/14
- Languages : English
- Source: Proceedings of the 1998 Purdue International Refrigeration Conference.
View record
-
An homogeneous model for adiabatic capillary tu...
- Author(s) : BANSAL P. K., RUPASINGHE A. S.
- Date : 1998/03
- Languages : English
- Source: Applied Thermal Engineering - vol. 18 - n. 3-4
View record
-
Reviewing two simple methods of calculating the...
- Author(s) : PALM B., GRANRYD E.
- Date : 1999/09/19
- Languages : English
- Source: 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
View record
-
Effect of delay length at the onset of two-phas...
- Author(s) : GUJRAL I. S., DAVE R. K., GORASIA J. N., et al.
- Date : 1999/09/19
- Languages : English
- Source: 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
View record