AIR AND AEROSOL INFILTRATION IN HOMES.
Author(s) : MCMURRY P. H.
Summary
THIS PAPER DISCUSSES THE MEASUREMENT OF AIR INFILTRATION RATES AND MEASUREMENTS RELATING INDOOR AND OUTDOOR AEROSOL SIZE DISTRIBUTIONS IN THE 0.01 TO 1 MICROMETRE SIZE RANGE. SIMULTANEOUS MEASUREMENTS OF AIR EXCHANGE RATES WITH THE INDUCED PRESSURE AND TRACER GAS TECHNIQUES WERE DONE IN TWO HOMES, AND THE TWO METHODS WERE FOUND TO AGREE TO WITHIN ESTIMATED EXPERIMENTAL UNCERTAINTIES. INDOOR AND OUTDOOR AEROSOL SIZE DISTRIBUTIONS WERE MEASURED AND COMPARED IN ONE HOME. IT WAS FOUND THAT FOR PARTICLES IN THE 0.01 TO 1.0 MICROM RANGE, THE RATIO OF INDOOR TO OUTDOOR CONCENTRATIONS WAS TYPICALLY BETWEEN 0.2 AND 0.4 AND DID NOT VARY SYSTEMATICALLY WITH PARTICLE SIZE.
Details
- Original title: AIR AND AEROSOL INFILTRATION IN HOMES.
- Record ID : 1986-0763
- Languages: English
- Publication date: 1985
- Source: Source: ASHRAE Trans.
vol. 91; n. 1A; 255-264; 5 fig.; 22 ref.; discuss. - Document available for consultation in the library of the IIR headquarters only.
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Measurement; Air change; Aerosol; Tracer gas; Air conditioning
-
THE EFFECT OF TRACER GAS ON THE ACCURACY OF AIR...
- Author(s) : SHAW C. Y.
- Date : 1984
- Languages : English
View record
-
AIR INFILTRATION MEASUREMENT TECHNIQUES.
- Author(s) : SHERMAN M. H.
- Date : 1989/09
- Languages : English
View record
-
An analysis of different tracer gas techniques ...
- Author(s) : JUNG A., ZELLER M.
- Date : 1994/06/15
- Languages : English
- Source: ROOMVENT '94. Air distribution in rooms. Proceedings.
View record
-
On the accuracy and repeatability of the pulse ...
- Author(s) : ZHANG J. S., SHAW C. Y., MAGEE R. J.
- Date : 1995/01
- Languages : English
- Source: ASHRAE Transactions.
View record
-
Air change rate measurement: the log/linear dec...
- Author(s) : FLETCHER B., SAUNDERS J., JOHNSON A.
- Date : 2000/06/04
- Languages : English
- Source: Progress in modern ventilation. Ventilation 2000. Proceedings of the 6th International symposium on ventilation for contaminant control.
View record