An efficient helium circulation system with small GM cryocoolers.
Author(s) : TAKEDA T., OKAMOTO M., ATSUDA K., et al.
Type of article: Article
Summary
The authors developed a helium circulating system that re-liquefies all the evaporating helium gas and consumes far less power than conventional systems, because warm helium gas at about 40 K collected high above the surface of the liquid helium in the Dewar is used to keep the Dewar cold, and because cold helium gas just above the liquid helium surface is collected and re-liquefied while still cold. A special transfer tube with multi-concentric pipes was developed to make the system operate efficiently. The system can produce up to 35.5 l/D of liquid helium from the evaporated helium using two 1.5 W at 4.2 K GM cryocoolers. [Reprinted with permission from Elsevier. Copyright, 2007].
Details
- Original title: An efficient helium circulation system with small GM cryocoolers.
- Record ID : 2008-1436
- Languages: English
- Source: Cryogenics - vol. 48 - n. 1-2
- Publication date: 2008/01
Links
See other articles in this issue (5)
See the source
Indexing
- Themes: Small-scale cryogenic applications, cryocoolers
- Keywords: Helium; Gifford-McMahon; Liquefaction; Process; Evaporation; Cryocooler; Cryogenics
-
Helium liquefaction with a commercial 4 K Giffo...
- Author(s) : SCHMIDT-WELLENBURG P., ZIMMER O.
- Date : 2006/11
- Languages : English
- Source: Cryogenics - vol. 46 - n. 11
View record
-
A self-circulation helium liquefaction system w...
- Author(s) : XU D., GONG L., LI L., et al.
- Date : 2011/06
- Languages : English
- Source: Cryogenics - vol. 51 - n. 6
View record
-
Helium 3-helium 4 dilution refrigerator with Gi...
- Author(s) : UHLIG K., HEHN W.
- Date : 1993/11
- Languages : English
- Source: Cryogenics - vol. 33 - n. 11
View record
-
Helium liquefaction by a two-stage Gifford-McMa...
- Author(s) : KURIYAMA T., TAKAHASHI M., NAKAGOME H., EDA T., SESHAKE H., HASHIMOTO T.
- Date : 1992
- Languages : English
- Source: Jap. J. appl. Phys. - vol. 31 - n. 8B
View record
-
Helium 3-helium 4 dilution refrigerator precool...
- Author(s) : UHLIG K., HEHN W.
- Date : 1997/05
- Languages : English
- Source: Cryogenics - vol. 37 - n. 5
View record