BUILDING ENVELOPE AIR LEAKAGE AND MOISTURE TRANSFER.

Author(s) : MITALAS G. P.

Summary

THE PAPER PRESENTS CALCULATED DATA FOR ESTIMATING THE PROBABLE WALL CAVITY MOISTURE TRANSFER BY THE VARIOUS AIR EXCHANGE MODES: (1) ONLY THE CONVECTIVE AND THROUGH FLOW OF INSIDE AIR HAS THE POTENTIAL TO TRANSFER SIGNIFICANT AMOUNTS OF MOISTURE INTO A CAVITY ; (2) OUTDOOR AIR FLOW THROUGH A CAVITY HAS A STRONG POTENTIAL TO DRY THE CAVITY ; AND (3) THE CAVITY DRYING POTENTIAL IN VERY COLD AND/OR IN HIGH AMBIENT HUMIDITY REGIONS IS MARKEDLY LOWER THAN THE POTENTIAL OF MORE MODERATE CLIMATE REGIONS.

Details

  • Original title: BUILDING ENVELOPE AIR LEAKAGE AND MOISTURE TRANSFER.
  • Record ID : 1990-1199
  • Languages: English
  • Publication date: 1989/08/01
  • Source: Source: CLIMA 2000, Sarajevo
    vol. 1; 30-37; 7 fig.; 3 ref.