IIR document
Chiller system performance benchmark by data envelopment analysis.
Author(s) : YU F. W., CHAN K. T.
Type of article: Article, IJR article
Summary
The operation of chiller systems could account for the major proportion of electricity consumption in commercial and industrial facilities. This paper considers using data envelopment analysis (DEA) to facilitate benchmarking their energy performance. A system serving an institutional building was studied, which contains five sets of chillers, pumps and cooling waters. The scale, technical and overall efficiencies defined in DEA were calculated based on the correlation between the output [system coefficient of performance (COP)] and the inputs (load factor and temperatures of chilled water and condenser water). Results of DEA indicated that the existing operating strategy gave an average technical efficiency of 0.85 and fine-tuning the temperature-related variables could improve the average system COP from 3.87 to 4.56, the highest possible performance with technical efficiency of one. The significance of this study is to demonstrate how DEA helps rectify control and operational problems of chiller systems and to estimate their highest achievable performance.
Available documents
Format PDF
Pages: 1815-1823
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Chiller system performance benchmark by data envelopment analysis.
- Record ID : 30005891
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 7
- Publication date: 2012/11
Links
See other articles in this issue (24)
See the source
Indexing
- Themes: Chillers
- Keywords: Efficiency; Chiller; Statistics; Performance; Energy saving
-
High performance heat pumps and chillers are av...
- Author(s) : MELQUIOND E.
- Date : 2011/10
- Languages : English
- Source: REHVA Journal - vol. 48 - n. 5
View record
-
Optimal chiller loading by improved parallel pa...
- Author(s) : GAO Z., YU J., HU Q., YANG S.
- Date : 2022/04
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 136
- Formats : PDF
View record
-
Energy-conservation system applied to centrifug...
- Author(s) : HASEGAWA Y., UEDA K., MATSUO M., et al.
- Date : 2011/03
- Languages : Japanese
- Source: Refrigeration - vol. 86 - n. 1001
View record
-
IMPROVING EFFICIENCY IN EXISTING CHILLERS WITH ...
- Author(s) : KAYA A.
- Date : 1991/10
- Languages : English
- Source: ASHRAE Journal - vol. 33 - n. 10
View record
-
Saving energy and cost on high-performance chil...
- Author(s) : HO S.
- Date : 2004/10
- Languages : English
- Source: Climate Control News - vol. 3 - n. 10
View record