A thermally inferior suspension system can nullify the effect of using high performance thermal insulation. The paper describes a new design of support system in which the central suspension rod is under tensile stress while the concentric tubular support is subjected to compressive stress due to acceleration loads. The design not only provides a long thermal conduction path, but also eliminates thermal contraction stresses, while allowing marginal assembly misalignments.
Details
- Original title: Concentric tubular support design for cryogenic tanks.
- Record ID : 1994-0017
- Languages: English
- Source: Cryogenics - vol. 33 - n. 4
- Publication date: 1993/04
Links
See other articles in this issue (13)
See the source
Indexing
-
Cryogenic storage systems in space applications.
- Author(s) : COLAPRETE S.
- Date : 1993/06
- Languages : English
- Source: CryoGas International - vol. 31 - n. 6
View record
-
Space-based liquid hydrogen propellant storage ...
- Author(s) : LIGGETT M. W.
- Date : 1993/04
- Languages : English
- Source: Cryogenics - vol. 33 - n. 4
View record
-
Comparison of dewar supports for space applicat...
- Author(s) : KITTEL P.
- Date : 1993/04
- Languages : English
- Source: Cryogenics - vol. 33 - n. 4
View record
-
Vibration test cryostat.
- Author(s) : SCHLEGELMILCH R.
- Date : 1991/03
- Languages : English
- Source: Cryogenics - vol. 31 - n. 3
View record
-
Anomalous on-orbit behaviour of the NASA Cosmic...
- Author(s) : VOLZ S. M., DIPIRRO M. J.
- Date : 1992
- Languages : English
- Source: Cryogenics - vol. 32 - n. 2
View record