Demand controlled ventilation in a combined ventilation and radiator system.
Number: pap. 1102
Author(s) : HESARAKI A., HOLMBERG S.
Summary
With growing concerns for efficient and sustainable energy treatment in buildings there is a need for balanced and intelligent ventilation solutions. This paper presents a strategy for demand controlled ventilation with ventilation radiators, a combined heating and ventilation system. The ventilation rate was decreased from normal requirements (per floor area) of 0.375 l•s-1•m-2 to 0.100 l•s-1•m-2 when the residence building was un-occupied. The energy saving potential due to decreased ventilation and fan power was analyzed by IDA Indoor Climate and Energy 4 (ICE) simulation program. The result showed that 16 % of the original energy consumption for space and ventilation heating could be saved by utilizing ventilation on demand.
Available documents
Format PDF
Pages: 5 p.
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Demand controlled ventilation in a combined ventilation and radiator system.
- Record ID : 30010659
- Languages: English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Publication date: 2013/06/16
Links
See other articles from the proceedings (424)
See the conference proceedings
Indexing
- Themes: Comfort air conditioning
- Keywords: Variable volume; Controlled mechanical ventilation; Ventilation; Air; Performance; Energy saving
-
Energy conservation potential by optimization o...
- Author(s) : GU B., SCHMID J., SCHMIDT M.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 3rd International High Performance Buildings Conference at Purdue.
- Formats : PDF
View record
-
Application of the exergy concept to ventilatio...
- Author(s) : SAKULPIPATSIN P., CAUBERG J. J. M., KOOI H. J. van der, et al.
- Date : 2007/06/10
- Languages : English
- Source: Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
View record
-
Research and development of a home use VAV air-...
- Author(s) : OKADA T., YOSHIKAWA T., SESHIMO Y., IGARASHI H.
- Date : 1992
- Languages : English
- Source: ASHRAE Transactions 1992. Part 2.
View record
-
ANALYTICAL EVALUATION OF OUTDOOR AIRFLOW RATE V...
- Author(s) : MUMMA S. A., WONG Y. M.
- Date : 1990
- Languages : English
View record
-
APPLICATION OF VAV, DDC AND SMOKE MANAGEMENT TO...
- Author(s) : LEWIS J. R.
- Date : 1988
- Languages : English
View record