IIR document

Dynamic performance analysis of an ejector refrigeration system with a direct-expansion solar generator.

Author(s) : VALENCIA-CANOLA S., MÉNDEZ F., BUSTAMANTE C. A.

Type of article: IJR article

Summary

Ejector Refrigeration Systems (ERS) can obtain their primary energy source from renewable sources such as solar radiation, which transfers heat to the ERS generator to achieve optimal operation. Direct-expansion solar collectors have been gain attention in systems such as solar heat pumps, avoiding the use of additional subsystems and energy sources and reducing costs and electricity consumption. In this study, the dynamic performance of an ERS with direct-expansion solar generator is assessed by means of a validated mathematical model that couples ERS subsystem operation. The proposed model predicts the global behavior of the cycle by describing mass, momentum and energy transport in each subsystem and by coupling their inlet and outlet conditions. An ERS basic design for average meteorological condition with direct-expansion solar generator is numerically analyzed for different transient operating conditions, in terms of solar radiation and ambient temperature, obtained from the typical meteorological year (TMY) of Mexico City. The results show that in favorable environmental conditions, the system can operate 2.3 h longer than the average day because the generator can maintain the refrigerant vapor phase for a longer period. However, refrigerant overheating increases, causing a reduction in the entrainment ratio (ER) and coefficient of performance (COP). This study shows that the ERS with a direct-expansion solar generator can operate for more than 90% of the TMY, reaching ER values of up to 0.6 and COP of up to 0.5, which are close to conventional ERS.

Available documents

Format PDF

Pages: 14 p.

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Dynamic performance analysis of an ejector refrigeration system with a direct-expansion solar generator.
  • Record ID : 30034576
  • Languages: English
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 183
  • Publication date: 2026/03
  • DOI: http://dx.doi.org/https://doi.org/10.1016/j.ijrefrig.2025.12.025

Links


See other articles in this issue (35)
See the source

Indexing

  • Themes: N/A
  • Keywords: N/A