Energy conservation using solar collectors integrated with building louver shading devices.
Author(s) : CHOU D. C., CHANG C. S., CHANG J. C.
Type of article: Article
Summary
Solar collector plates are typically installed on roofs, but they can also be installed on the walls and windows of a building. Integrating solar collectors with shading devices that are installed on windows to block solar radiation extends the application of solar collectors. This study developed a prototype system integrating horizontal louver shading devices with solar collectors. Atmospheric data and the physical parameters of collector efficiency were recorded to examine collector performance. The results showed that the day collector efficiency, instantaneous efficiency, and collector efficiency coefficient satisfied Taiwan government standards. Consequently, integrating horizontal louver shading devices with solar collectors is feasible, but suitable only for south-facing windows.
Details
- Original title: Energy conservation using solar collectors integrated with building louver shading devices.
- Record ID : 30017083
- Languages: English
- Source: Applied Thermal Engineering - vol. 93
- Publication date: 2016/01/25
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2015.09.014
Links
See other articles in this issue (72)
See the source
Indexing
-
SHADING CONTROL BY NEIGHBOURING BUILDINGS WITH ...
- Author(s) : ASFOURI A. S. el-, MARAQA R., TABBALAT R.
- Date : 1988/10/24
- Languages : English
View record
-
Saving with solar.
- Author(s) : AUSTIN B., WILLIS S.
- Date : 1993/09
- Languages : English
- Source: J. chart. Inst. Build. Serv. - vol. 15 - n. 9
View record
-
CALCULATION OF SHADOW BETWEEN SOLAR COLLECTOR R...
- Author(s) : LAZZARIN R.
- Date : 1981
- Languages : Italian
- Source: Cond. Aria - vol. 25 - n. 6
View record
-
Comparative analysis of PV shading devices for ...
- Author(s) : HAASE M., KHEZRI N.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
An evaluation of thermal environment on non-uni...
- Author(s) : SAITO N., SAKAI K., ONO H.
- Date : 2015/08/16
- Languages : English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
View record