Summary
In hot and humid regions, removal of moisture from the air represents a considerable portion of the air conditioning load. Conventionally, air conditioning systems have to lower the air temperature below its dew point to accomplish dehumidification. Desiccant air conditioners offer a solution to meet the humidity and temperature requirements of buildings via decoupling latent and sensible loads. In this work, the performance of a new polymer desiccant material is investigated experimentally. This desiccant material can be regenerated using a low temperature heat source. The effect of the process air stream’s temperature and humidity, the effect of the regeneration temperature, and the effect of the desiccant wheel’s rotational speed are investigated. ARI-humid conditions are used as a baseline and the moisture mass balance is maintained within 5%, based on ASHRAE 139-2007 standard. The results are presented in terms of the moisture removal rate, sensible effectiveness and latent coefficient of performance.
Available documents
Format PDF
Pages: 38-47 (9 p.)
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Investigación experimental del ciclo de una rueda desecante
- Record ID : 30011701
- Languages: Spanish
- Source: Frío Calor Aire acondicionado - n. 469
- Publication date: 2014/05
Links
- See translations: Experimental investigation of a desiccant wheel cycle.
See the source
-
Experimental investigation of a desiccant wheel...
- Author(s) : LEE H., CAO T., HWANG Y., et al.
- Date : 2013/06/17
- Languages : English
- Source: 4th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
View record
-
Characterization of desiccant wheels with alter...
- Author(s) : WHITE S. D., GOLDSWORTHY M., REECE R., et al.
- Date : 2011/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 8
- Formats : PDF
View record
-
Measurements of effectiveness in a silica gel r...
- Author(s) : NETI S., WOLFE E. I.
- Date : 2000/03
- Languages : English
- Source: Applied Thermal Engineering - vol. 20 - n. 4
View record
-
Novel desiccant cooling system using indirect e...
- Author(s) : BELDING W. A., DELMAS M. P. F.
- Date : 1997
- Languages : English
- Source: ASHRAE Transactions.
View record
-
Experimental analysis on the performances of a ...
- Author(s) : ANGRISANI G., MINICHIELLO F., ROSELLI C., et al.
- Date : 2011/04/06
- Languages : English
- Source: Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
View record