Heat pipe heat exchanger for heat recovery in air conditioning.
Author(s) : ABD EL-BAKY M. A., MOHAMED M. M.
Type of article: Article
Summary
The heat pipe heat exchangers are used in heat recovery applications to cool the incoming fresh air in air conditioning applications. Two streams of fresh and return air have been connected with heat pipe heat exchanger to investigate the thermal performance and effectiveness of heat recovery system. Ratios of mass flow rate between return and fresh air of 1, 1.5 and 2.3 have been adapted to validate the heat transfer and the temperature change of fresh air. Fresh air inlet temperature of 32-40°C has been controlled, while the inlet return air temperature is kept constant at about 26°C. The results showed that the temperature changes of fresh and return air are increased with the increase of inlet temperature of fresh air. The effectiveness and heat transfer for both evaporator and condenser sections are also increased to about 48%, when the inlet fresh air temperature is increased to 40°C. The effect of mass flow rate ratio on effectiveness is positive for evaporator side and negative for condenser side. The enthalpy ratio between the heat recovery and conventional air mixing is increased to about 85% with increasing fresh air inlet temperature. The optimum effectiveness of heat pipe heat exchanger is estimated and compared with the present experimental data. The results showed that the effectiveness is close to the optimum effectiveness at fresh air inlet temperature near the fluid operating temperature of heat pipes. [Reprinted with permission from Elsevier. Copyright, 2006].
Details
- Original title: Heat pipe heat exchanger for heat recovery in air conditioning.
- Record ID : 2008-0559
- Languages: English
- Source: Applied Thermal Engineering - vol. 27 - n. 4
- Publication date: 2007/03
Links
See other articles in this issue (1)
See the source
Indexing
-
Fundamental study on heat transfer characterist...
- Author(s) : SHIRAIWA H., HOSOKAWA T.
- Date : 2006/06
- Languages : English
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - vol. 111
View record
-
A testing and HVAC design methodology for air-t...
- Author(s) : GUO P. B., CIEPLISKI D. L., BESANT R. W.
- Date : 1998/01
- Languages : English
- Source: HVAC&R Research - vol. 4 - n. 1
View record
-
Air-to-air heat recovery in ventilation systems.
- Author(s) : SCHILD P. G.
- Date : 2004/06
- Languages : English
- Source: AIVC, CD/AIVC, VIP/AIR - AIVC CD n. 12/VIP n. 6/vol. 25 - AIVC CD n. 12/VIP n. 6/vol. 25
View record
-
Performance evaluation for cross-flow plate sen...
- Author(s) : ZHANG G., ZHANG Y.
- Date : 2009/08
- Languages : Chinese
- Source: HV & AC - vol. 39 - n. 227
- Formats : PDF
View record
-
Hodnoceni rekuperacnich vymeniku metodou exergi...
- Author(s) : ADAMOVSKY D.
- Date : 2007/04
- Languages : Czech
- Source: Vytápení Vetrání Instalace - vol. 16 - n. 4
View record